    "meta": {
        "title": "D-Central — ASIC Power & Electrical Requirements",
        "description": "Stock wall power, hashrate, required voltage (120V vs dedicated 240V), recommended circuit/breaker, matching Bitmain PSU and typical NEMA plug for 11 in-stock Antminer ASIC models.",
        "generated": "2026-06-21T15:04:00+00:00",
        "version": "1.0",
        "license": "https://creativecommons.org/licenses/by/4.0/",
        "license_name": "CC BY 4.0",
        "source": "https://d-central.tech/asic-power-requirements/",
        "record_count": 11,
        "provenance": "D-Central Mining Bible (POWER_PROFILES_CATALOG, PSU_PROTOCOL_BIBLE, MASTER_PLL_REGISTER_BIBLE, HARDWARE_REFERENCE). Bitmain manufacturer spec used where the Bible confirms the model/chip/PSU but carries no air-cooled nameplate wattage (T19, S21 Pro, S21 XP) — flagged per row.",
        "disclaimer": "Stock nameplate figures carry Bitmain's ~+/-5% tolerance and shift with firmware, autotune and ambient temperature. Breaker recommendations assume 240V single-phase; 208V (commercial 3-phase) raises current ~15%. NEMA plug types are inferred from standard receptacle ratings, not manufacturer-specified -- the actual wall plug depends on the installer's cordset. Always confirm against the unit nameplate and have a licensed electrician size the circuit."
    },
    "rows": [
        {
            "id": "antminer-s9",
            "model": "Antminer S9",
            "algorithm": "SHA-256",
            "hashrate": "13.5 TH/s",
            "power_w": 1400,
            "voltage": "100-264V (APW3++ universal input)",
            "voltage_note": "Runs on 120V. This is the ONLY model here that flexibly accepts 120-240V at full output, because the APW3++ PSU has universal 100-264V input. Ideal home/space-heater unit.",
            "circuit": "120V / 15A (dedicated) OR 240V / 15A",
            "plug": "C13/C14 IEC inlet on APW3++ PSU; standard NEMA 5-15 cord at 120V (NEMA 6-15 if run at 240V)",
            "psu": "APW3++ 1600W (or APW7 1800W) — both 100-264V universal",
            "notes": "Bible TDP = 1400W; Bitmain rated wall power for the 13.5T variant is ~1323W, so 1400W is conservative. Breaker: 1400W/120V=11.7A -> /0.8=14.6A -> 15A; at 240V only 5.8A. S9 stock variants vary (13.5T/14T, S9j 14.5T); D-Central S9s are typically refurb/as-is — verify per unit.",
            "source": "BITCOIN_HACKER_DATASET.md §6 (1400W TDP, 110V compatible); MASTER_CHIP_CATALOG (BM1387 S9); PSU_PROTOCOL_BIBLE (APW3++ 100-264V); hashrate = Bitmain spec",
            "heat_btu_h": 4777,
            "home_fit": "120V plug-and-play (heater-class)"
        },
        {
            "id": "antminer-t19",
            "model": "Antminer T19",
            "algorithm": "SHA-256",
            "hashrate": "84 TH/s",
            "power_w": 3150,
            "voltage": "200-240V (APW12)",
            "voltage_note": "REQUIRES 200-240V. Stock APW12 PSU will not start / under-delivers on 120V. Not a 120V unit.",
            "circuit": "240V / 20A (dedicated)",
            "plug": "C19/C20 IEC inlet on APW12 PSU; 240V wall plug per install (commonly NEMA 6-20 for a dedicated 240V/20A circuit)",
            "psu": "APW12 (12-15V, 3600W @220V)",
            "notes": "84TH/3150W is Bitmain spec — Bible confirms model+chip (BM1398) but carries no T19 nameplate wattage. Breaker: 3150W/240V=13.1A -> /0.8=16.4A -> 20A. ~37.5 J/TH (lowest-efficiency S19-gen unit).",
            "source": "BRAIINSOS_REVERSE_ENGINEERING.md (T19=BM1398); PSU_PROTOCOL_BIBLE (APW12 covers T19); 84TH/3150W = Bitmain spec (not in Bible)",
            "heat_btu_h": 10748,
            "home_fit": "240V dedicated circuit"
        },
        {
            "id": "antminer-s19",
            "model": "Antminer S19",
            "algorithm": "SHA-256",
            "hashrate": "95 TH/s",
            "power_w": 3250,
            "voltage": "200-240V (APW12)",
            "voltage_note": "REQUIRES 200-240V — Bible lists S19 as not 110V compatible (needs 240V). On 120V via APW3++ bypass it derates to ~1200W / 35-45 TH only.",
            "circuit": "240V / 20A (dedicated)",
            "plug": "C19/C20 IEC inlet on APW12 PSU; 240V wall plug per install (commonly NEMA 6-20)",
            "psu": "APW12 (12-15V, 3600W @220V)",
            "notes": "Bible stock = ~95 TH @ 3250W (34.2 J/TH); the 126TH-bin S19 tunes 67-130TH (1630-4700W). Breaker: 3250W/240V=13.5A -> /0.8=16.9A -> 20A. 120V derate path: APW3++ @1200W = 35-45 TH.",
            "source": "POWER_PROFILES_CATALOG.md §2.1 + bible-facts.md (95TH/3250W); BITCOIN_HACKER_DATASET (needs 240V); PSU_PROTOCOL_BIBLE",
            "heat_btu_h": 11089,
            "home_fit": "240V dedicated circuit"
        },
        {
            "id": "antminer-s19-pro",
            "model": "Antminer S19 Pro",
            "algorithm": "SHA-256",
            "hashrate": "110 TH/s",
            "power_w": 3245,
            "voltage": "200-240V (APW12)",
            "voltage_note": "REQUIRES 200-240V. Stock APW12 will not run at full power on 120V.",
            "circuit": "240V / 20A (dedicated)",
            "plug": "C19/C20 IEC inlet on APW12 PSU; 240V wall plug per install (commonly NEMA 6-20)",
            "psu": "APW12 (12-15V, 3600W @220V)",
            "notes": "Bible nameplate (BM1398 step-0): 675 MHz / 13.8V / 3245W / 110 TH/s ~= 29.5 J/TH. Breaker: 3245W/240V=13.5A -> /0.8=16.9A -> 20A. 114 chips/board (vs 76 on plain S19).",
            "source": "MASTER_PLL_REGISTER_BIBLE.md (110TH/3245W nameplate); bible-facts.md; PSU_PROTOCOL_BIBLE",
            "heat_btu_h": 11072,
            "home_fit": "240V dedicated circuit"
        },
        {
            "id": "antminer-s19j-pro",
            "model": "Antminer S19j Pro",
            "algorithm": "SHA-256",
            "hashrate": "100 TH/s",
            "power_w": 3050,
            "voltage": "200-240V (APW12 / APW121215a)",
            "voltage_note": "REQUIRES 200-240V. On 120V via APW3++ bypass it derates to ~1200W / 40-50 TH only.",
            "circuit": "240V / 20A (dedicated)",
            "plug": "C19/C20 IEC inlet on APW12 PSU; 240V wall plug per install (commonly NEMA 6-20)",
            "psu": "APW12 (live probe: APW121215a, FW 0x71)",
            "notes": "Bitmain nameplate 100 TH @ 3050W; Bible live BraiinsOS probe reported 104 TH/s and PSU rated 3068W. Catalog S19j Pro-A stock ~100TH @ 2970W. BM1362 5nm. Breaker: 3050W/240V=12.7A -> /0.8=15.9A -> 20A.",
            "source": "HARDWARE_REFERENCE.md (104TH live / 3068W PSU); POWER_PROFILES_CATALOG §2.4; MASTER_CHIP_CATALOG (BM1362); nameplate 3050W = Bitmain spec",
            "heat_btu_h": 10407,
            "home_fit": "240V dedicated circuit"
        },
        {
            "id": "antminer-s19j-pro-plus",
            "model": "Antminer S19j Pro+",
            "algorithm": "SHA-256",
            "hashrate": "120 TH/s",
            "power_w": 3355,
            "voltage": "200-240V (APW12)",
            "voltage_note": "REQUIRES 200-240V. Stock APW12 will not run at full power on 120V.",
            "circuit": "240V / 20A (dedicated)",
            "plug": "C19/C20 IEC inlet on APW12 PSU; 240V wall plug per install (commonly NEMA 6-20)",
            "psu": "APW12 (12-15V, 3600W @220V)",
            "notes": "120TH/3355W is Bitmain nameplate (27.5 J/TH); Bible catalog gives a 21-profile band (65TH@1450W -> 159TH@5900W) with no explicit 'stock' row — nearest profiles bracket 116TH@3200W and 122TH@3500W. BM1362 5nm. Breaker: 3355W/240V=14.0A -> /0.8=17.5A -> 20A.",
            "source": "POWER_PROFILES_CATALOG.md §2.5 (profile band); MASTER_CHIP_CATALOG (BM1362); 120TH/3355W stock = Bitmain spec",
            "heat_btu_h": 11448,
            "home_fit": "240V dedicated; garage / Hashcenter"
        },
        {
            "id": "antminer-s19k-pro",
            "model": "Antminer S19k Pro",
            "algorithm": "SHA-256",
            "hashrate": "120 TH/s",
            "power_w": 2760,
            "voltage": "200-240V (APW12)",
            "voltage_note": "REQUIRES 200-240V. On 120V via APW3++ bypass it derates to ~1200W / 52-56 TH only.",
            "circuit": "240V / 20A (dedicated); 15A minimum",
            "plug": "C19/C20 IEC inlet on APW12 PSU; 240V wall plug per install (commonly NEMA 6-20)",
            "psu": "APW12 (12-15V, 3600W @220V)",
            "notes": "Bible explicitly: stock 120 TH @ ~2760W (23 J/TH). Breaker: 2760W/240V=11.5A -> /0.8=14.4A; a 15A breaker (12A continuous) technically holds but 20A recommended for headroom. BM1366 5nm.",
            "source": "POWER_PROFILES_CATALOG.md §2.6 ('Stock is 120 TH @ ~2760W'); bible-facts (BM1366); PSU_PROTOCOL_BIBLE",
            "heat_btu_h": 9418,
            "home_fit": "240V dedicated circuit"
        },
        {
            "id": "antminer-s21-pro",
            "model": "Antminer S21 Pro",
            "algorithm": "SHA-256",
            "hashrate": "234 TH/s",
            "power_w": 3531,
            "voltage": "220-277V (APW17)",
            "voltage_note": "REQUIRES 220-240V (200-277V PSU range). No 120V operation — will not start on 120V.",
            "circuit": "240V / 20A (dedicated); 30A if on 208V or overclocked",
            "plug": "C19/C20 IEC inlet (or integrated PSU); 240V wall plug per install (NEMA 6-20; step up to 6-30 for 208V/OC)",
            "psu": "APW17 (12-15V, 3600W, 267A) — NOT APW12; S21-series needs APW17",
            "notes": "234TH/3531W is Bitmain spec (~15.1 J/TH) — Bible confirms model+chip (BM1370) and APW17 PSU but no air-cooled S21 Pro nameplate wattage (only Hydro variants in the catalog). Breaker: 3531W/240V=14.7A -> /0.8=18.4A -> 20A; at 208V draw 17.0A -> 30A.",
            "source": "BRAIINSOS_REVERSE_ENGINEERING.md (S21 Pro=BM1370); PSU_PROTOCOL_BIBLE (APW17 220-277V, S21 series); 234TH/3531W = Bitmain spec",
            "heat_btu_h": 12048,
            "home_fit": "240V dedicated; garage / Hashcenter"
        },
        {
            "id": "antminer-s21-xp",
            "model": "Antminer S21 XP",
            "algorithm": "SHA-256",
            "hashrate": "270 TH/s",
            "power_w": 3645,
            "voltage": "220-277V (APW17)",
            "voltage_note": "REQUIRES 220-240V (200-277V PSU range). No 120V operation.",
            "circuit": "240V / 20A (dedicated); 30A if on 208V or overclocked",
            "plug": "C19/C20 IEC inlet (or integrated PSU); 240V wall plug per install (NEMA 6-20; step up to 6-30 for 208V/OC)",
            "psu": "APW17 (12-15V, 3600W, 267A) — NOT APW12",
            "notes": "270TH/3645W is Bitmain spec (~13.5 J/TH) — Bible confirms model+chip (BM1370) + APW17 but no air-cooled XP nameplate wattage. Breaker: 3645W/240V=15.2A -> /0.8=19.0A -> 20A (only ~0.8A headroom under the 16A continuous limit — tight; recommend 30A for OC/208V). At 208V: 17.5A -> 30A.",
            "source": "BRAIINSOS_REVERSE_ENGINEERING.md (S21 XP=BM1370); bible-facts (S21 XP BM1370, 91 chips/board); PSU_PROTOCOL_BIBLE; 270TH/3645W = Bitmain spec",
            "heat_btu_h": 12437,
            "home_fit": "240V dedicated; garage / Hashcenter"
        },
        {
            "id": "antminer-l3-plus",
            "model": "Antminer L3+",
            "algorithm": "Scrypt",
            "hashrate": "504 MH/s",
            "power_w": 800,
            "voltage": "100-264V (APW3++ / APW7 universal input)",
            "voltage_note": "Runs on 120V fine — only 800W, well within a standard 120V/15A outlet. Universal-input PSU.",
            "circuit": "120V / 15A (dedicated) OR 240V / 15A",
            "plug": "C13/C14 IEC inlet on APW3++/APW7 PSU; standard NEMA 5-15 cord at 120V",
            "psu": "APW3++ 1600W or APW7 1800W (both 100-264V universal)",
            "notes": "Bible nameplate (Operator-confirmed): 504 MH/s @ 800W. BM1485 28nm, 144 chips. Breaker: 800W/120V=6.7A -> /0.8=8.3A -> 15A; at 240V only 3.3A. Older/as-is unit — efficiency (~1.6 J/MH) is poor vs L7; verify wall power per unit.",
            "source": "MASTER_PLL_REGISTER_BIBLE.md (504 MH/s @ 800W, OperatorConfirmed); MASTER_CHIP_CATALOG (BM1485 L3+); PSU_PROTOCOL_BIBLE (APW7 supports L3+)",
            "heat_btu_h": 2730,
            "home_fit": "120V plug-and-play (heater-class)"
        },
        {
            "id": "antminer-l7",
            "model": "Antminer L7",
            "algorithm": "Scrypt",
            "hashrate": "9.5 GH/s",
            "power_w": 3425,
            "voltage": "200-240V (APW12 14-17V)",
            "voltage_note": "REQUIRES 200-240V. The L7 uses the 14-17V APW12 ('APW12+') variant and will not run on 120V.",
            "circuit": "240V / 20A (dedicated)",
            "plug": "C19/C20 IEC inlet on PSU; 240V wall plug per install (commonly NEMA 6-20)",
            "psu": "APW12 (14-17V / 'APW12+', 3600W @220V) — the higher-voltage L7/K7/DR7 variant, NOT the 12-15V S19 APW12",
            "notes": "Bible nameplate: 9.5 GH/s (9500 MH/s) @ 3425W (~0.36 J/MH). BM1489 7nm, 480 chips. VNish tunes 4800-12000 MH/s (1855-6000W). Breaker: 3425W/240V=14.3A -> /0.8=17.8A -> 20A.",
            "source": "MASTER_CHIP_CATALOG.md + POWER_PROFILES_CATALOG §4.1 (9.5 GH/s @ 3425W); PSU_PROTOCOL_BIBLE (APW12 1417 for L7)",
            "heat_btu_h": 11687,
            "home_fit": "240V dedicated; garage / Hashcenter"
        }
    ]
}