S17 Kernel – Antminer S17 hashboard Chain 2 lacks chips

Un tableau de hachage Antminer S17 possède 48 puces, mais le journal du noyau n’en trouve que 16 (comme le montre la figure ci-dessous) ; ainsi, lorsque nous rencontrons ce problème, comment le résoudre ?

2022-05-07 08:49:51 driver-btm-api.c:915:check_asic_number_with_power_on: Chain[2]: find 16 asic, times 0
2022-05-07 08:50:02 driver-btm-api.c:915:check_asic_number_with_power_on: Chain[2]: find 16 asic, times 1
2022-05-07 08:50:13 driver-btm-api.c:915:check_asic_number_with_power_on: Chain[2]: find 16 asic, times 2
2022-05-07 08:50:13 driver-btm-api.c:942:check_asic_number: Chain 2 only find 16 asic, will power off hash board 2
2022-05-07 08:50:14 driver-btm-api.c:198:set_miner_status:ERROR_SOC_INIT
2022-05-07 08:50:14 driver-btm-api.c:139:stop_mining: stop mining: soc init failed!
2022-05-07 08:50:14 thread.c:828:cancel_read_nonce_reg_thread: cancel thread
2022-05-07 08:50:14 driver-btm-api.c:124:killall_hashboard: ****power off hashboard****

Dépannage :

Il s’agit très probablement d’un problème de puce, nécessitant des réparations au niveau du hachoir. Réglez le multimètre Fluke 17B+ sur le rapport DC, concentrez-vous à vérifier si la tension et la résistance des cinq signaux (CLK-CO-RI-BO-RST) des puces n° 16 et n° 17 sont normales, et comparez avec la valeur de résistance de la puce normale. La puce spécifique défectueuse peut être jugée et remplacée par la puce ASIC BM1397 défectueuse.

Liens utiles :