Error code:110 Meaning:Inlet fan detcction speed error Corresponding solutions: Check whether the fan connction is normal, or replace the power supply, or replace the fan
Error code:111 Meaning:Outlet fan detection speed error Corresponding solutions:
Error code:120 Meaning:Inlet fan speed error(Deviation 2000+) Corresponding solutions:
Error code:121 Meaning:Outlet fan speed error(Deviation 2000+) Corresponding solutions:
Error code:130 Meaning:Inlet fan speed error Corresponding solutions:
Error code:131 Meaning:Outlet fan spced error Corresponding solutions:
Error code:140 Meaning:Fan speed is too high Corresponding solutions: Please check the environment temperature
Error code:200 Meaning:Power detection error Corresponding solutions: Detecting the power output cable, or updating the latest firmware, or replacing the power supply
Error code:201 Meaning:Power does not match the configuration file Corresponding solutions: Updating to the latest software
Error code:202 Meaning:Power output voltage error Corresponding solutions: Updating to the latest software or check the power supply
Error code:203 Meaning:Power supply protection Corresponding solutions: Please check the environment temperature
Error code:204 Meaning:Power supply current protection Corresponding solutions:
Error code:205 Meaning:Power current error Corresponding solutions: Inspection of power supply in power grid
Error code:206 Meaning:Power input voltage is low Corresponding solutions: Improve power supply conditions and input voltage
Error code:207 Meaning:Power input current protecting Corresponding solutions:
Error code:210 Meaning:Power status error Corresponding solutions: Check the power failure code
Error code:213 Meaning:Power input voltage and current do not match the power Corresponding solutions: Replace the PSU
Error code:216 Meaning:Power remained unchanged for a long time Corresponding solutions:
Error code:217 Meaning:Power set enable error Corresponding solutions:
Error code:218 Meaning:Power input voltage is lower than 230V for high power mode Corresponding solutions: Increase input voltage,replace power supply
Error code:233 Meaning:Overtemperature Protection of Power Output Corresponding solutions: Plcase check the environment temperature
Error code:234 Meaning:Overtemperature Protection of Power Output Corresponding solutions:
Error code:235 Meaning:Overtemperature Protection of Power Output Corresponding solutions:
Error code:236 Meaning:Overcurrent Protection of Power Output Corresponding solutions: Please check the environment temperature and the copper wire screw(Recommend to use the protable electric screwdriver)
Error code:237 Meaning:Overcurrent Protection of Power Output Corresponding solutions:
Error code:238 Meaning:Overcurrent Protection of Power Output Corresponding solutions:
Error code:239 Meaning:Overvoltage Protection of Power Output Corresponding solutions: Check grid power
Error code:240 Meaning:Low Voltage Protection for Power Output Corresponding solutions:
Error code:241 Meaning:Power output current imbalance Corresponding solutions: Replace the power
Error code:243 Meaning:Over-tempcrature Protection for Power Input Corresponding solutions: Please check the environment temperature
Error code:244 Meaning:Over-temperature Protection for Power Input Corresponding solutions:
Error code:245 Meaning:Over-tempcrature Protection for Power Input Corresponding solutions:
Error code:246 Meaning:Overcurrent Protection for Power Input Corresponding solutions:
Error code:247 Meaning:Overcurrent Protection for Power Input Corresponding solutions:
Error code:248 Meaning:Overvoltage Protection for Power Input Corresponding solutions: Check grid power
Error code:249 Meaning:Overvoltage Protection for Power Input Corresponding solutions:
Error code:250 Meaning:Undervoltage Protection for Power Input Corresponding solutions:
Error code:251 Meaning:Undervoltage Protection for Power Input Corresponding solutions:
Error code:253 Meaning:Power Fan Error Corresponding solutions: Replace the power supply
Error code:254 Meaning:Power Fan Error Corresponding solutions:
Error code:255 Meaning:Protection of over power output Corresponding solutions: Please check the environment temperature
Error code:256 Meaning:Protection of over power output Corresponding solutions:
Error code:257 Meaning:Input over current protection of power supply primary side Corresponding solutions: Try to power off and restart, no effect to replace the power supply
Error code:263 Meaning:Power communication warning Corresponding solutions: Check whether the screws of the control board are locked
Error code:264 Meaning:Power communication error Corresponding solutions:
Error code:267 Meaning:Power watchdog protection Corresponding solutions: Contact the technician in time
Error code:268 Meaning:Power output over-current protection Corresponding solutions: Check the ambient temperature, check the copper bar screw
Error code:269 Meaning:Power input over-current protection Corresponding solutions: Improve power supply conditions and input voltage
Error code:270 Meaning:Power input over-voltage protection Corresponding solutions: Inspection of input voltage in power grid
Error code:271 Meaning:Power input under-voltage protection Corresponding solutions:
Error code:272 Meaning:Warning of excessive power
output of power supply
Corresponding solutions: Please check the environment temperature
Error code:273 Meaning:Power input power too high warning Corresponding solutions:
Error code:274 Meaning:Power fan warning Corresponding solutions: Check if the power fan is blocked and may need to be replaced
Error code:275 Meaning:Power over temperature warning Corresponding solutions: Please check the environment temperature
Error code:300 Meaning:SM0 temperature sensor detection error Corresponding solutions: Check the connection of the hash board
Error code:301 Meaning:SM1 temperature sensor detection error Corresponding solutions:
Error code:302 Meaning:SM2 temperature sensor detection error Corresponding solutions:
Error code:320 Meaning:SM0 board temperature sensor communication error Corresponding solutions: Check if the control panel screws are locked, check the adapter plate and the cable contacts
Error code:321 Meaning:SM1 board temperature sensor communication error Corresponding solutions:
Error code:322 Meaning:SM2 board temperature sensor communication error Corresponding solutions:
Error code:329 Meaning:Control board temperature
sensor communication error
Corresponding solutions: Replace the power supply
Error code:350 Meaning:SM0 tempcrature protection Corresponding solutions: Check the environment temperature (Recommend to use the GS320 infrared thermometer)
Error code:351 Meaning:M1 tempcrature protection Corresponding solutions:
Error code:352 Meaning:SM2 tempcrature protection Corresponding solutions:
Error code:360 Meaning:The temperature of the hash board is overheating Corresponding solutions:
Error code:410 Meaning:SMO detect eeprom error Corresponding solutions: Check adapter plate and cable contact
Error code:411 Meaning:SM1 detect eeprom error Corresponding solutions:
Error code:412 Meaning:SM2 detect eeprom error Corresponding solutions:
Error code:420 Meaning:SM0 parser eeprom error Corresponding solutions: Upgrade firmware
Error code:421 Meaning:SM1 parser eeprom error Corresponding solutions:
Error code:422 Meaning:SM2 parser eeprom error Corresponding solutions:
Error code:430 Meaning:SM0 chip bin type error Corresponding solutions:
Error code:431 Meaning:SM1 chip bin type error Corresponding solutions:
Error code:432 Meaning:SM2 chip bin type error Corresponding solutions:
Error code:440 Meaning:SM0 eeprom chip num X error Corresponding solutions:
Error code:441 Meaning:SM1 eeprom chip num X error Corresponding solutions:
Error code:442 Meaning:SM2 eeprom chip num X error Corresponding solutions:
Error code:450 Meaning:SM0 eeprom xfer error Corresponding solutions: Check adapter board and wiring contacts.Upgrade firmware
Error code:451 Meaning:SM1 eeprom xfer error Corresponding solutions:
Error code:452 Meaning:SM2 eeprom xfer error Corresponding solutions:
Error code:510 Meaning:SM0 miner type error Corresponding solutions: The version and type of hashboard are
inconsistent, replace the correct hashboard
Error code:511 Meaning:SM1 miner type error Corresponding solutions:
Error code:512 Meaning:SM2 miner type error Corresponding solutions:
Error code:520 Meaning:SM0 bin type error Corresponding solutions: If the chip type of the hash board is inconsistent, replace the correct hash board.
Error code:521 Meaning:SM1 bin type error Corresponding solutions:
Error code:522 Meaning:SM2 bin type error Corresponding solutions:
Error code:530 Meaning:SM0 board is not detected Corresponding solutions: Check the adapter board wiring and cablc, or replace the control board to check whether the hash board connector is soldered
Error code:531 Meaning:SM1 board is not detected Corresponding solutions:
Error code:532 Meaning:SM2 board is not detected Corresponding solutions:
Error code:540 Meaning:The number of SM0 chips is incomplete Corresponding solutions: Check adapter plate and cable contact
Error code:541 Meaning:The number of SM1 chips is incomplete Corresponding solutions:
Error code:542 Meaning:The number of SM2 chips is incomplete Corresponding solutions:
Error code:550 Meaning:SM0 has bad chips Corresponding solutions: Replace the bad chip in the print position
Error code:551 Meaning:SM1 has bad chips Corresponding solutions:
Error code:552 Meaning:SM2 has bad chips Corresponding solutions:
Error code:560 Meaning:SM0 loss balance Corresponding solutions: Plug in the adapter plate, and then screw in the power connection hash board again
Error code:561 Meaning:SM1 loss balance Corresponding solutions:
Error code:562 Meaning:SM2 loss balance Corresponding solutions:
Error code:590 Meaning:SM0 frequency is too low Corresponding solutions: Replace the hash board and place the hash boards which reported the same error together
Error code:591 Meaning:SM1 frequency is too low Corresponding solutions:
Error code:592 Meaning:SM2 frequency is too low Corresponding solutions:
Error code: Meaning: Corresponding solutions:
Error code:600 Meaning:Environment temperature is too high Corresponding solutions: Check the environment temperature
Error code:610 Meaning:If the ambient temperature is too high in high performance mode, return to normal mode Corresponding solutions: Check the ambient temperature, high
performance mode needs to be ontrolled below 30 ℃
Error code:701 Meaning:Control board no support chip Corresponding solutions: Upgrade the corresponding type of firmware
Error code:710 Meaning:Control board error Corresponding solutions: Update to the latest firmware
Error code:712 Meaning:Control board rebooted as exception Corresponding solutions: Updating the latest firmware.Check whether the control board screw is locked properly
Error code:800 Meaning:cgminer checksum error Corresponding solutions: Re-upgrade firmware
Error code:801 Meaning:system-monitor checksum error Corresponding solutions:
Error code:802 Meaning:system-monitor checksum error Corresponding solutions:
Error code:2000 Meaning:No pool information configured Corresponding solutions: Check pool configuration
Error code:2010 Meaning:All mining pool connections failed Corresponding solutions: Check the network or mining pools setting
Error code:2020 Meaning:Mining pool0 connection failed Corresponding solutions:
Error code:2021 Meaning:Mining pool1 connection failed Corresponding solutions:
Error code:2022 Meaning:Mining pool2 connection failed Corresponding solutions:
Error code:2030 Meaning:Mining pool rejcction rate is too high Corresponding solutions: Check the network or mining pool setting, and the mining setting of the cryptocurrency
Error code:2040 Meaning:The pool does not support
the asicboost mode
Corresponding solutions: Check pool configuration
Error code:2310 Meaning:Hash rate is too low Corresponding solutions: Check input voltage, network environment, and ambient temperature
Error code:2320 Meaning:Hash rate is too low Corresponding solutions:
Error code:2340 Meaning:The loss of hash rate is too high Corresponding solutions:
Error code:2350 Meaning:The loss of hash rate is too high Corresponding solutions:
Error code:5070 Meaning:SM0 water velocity is abnormal Corresponding solutions: Check if the water flow is normal
Error code:5071 Meaning:SM1 water velocity is abnormal Corresponding solutions:
Error code:5072 Meaning:SM2 water velocity is abnormal Corresponding solutions:
Error code:5110 Meaning:SM0 Frequency Up Timeout Corresponding solutions: reboot
Error code:5111 Meaning:SM1 Frequency Up Timeout Corresponding solutions:
Error code:5112 Meaning:SM2 Frequency Up Timeout Corresponding solutions:
Error code:8410 Meaning:Software version error (M2x miner with M3x firmware, or M3x with M2x firmware) Corresponding solutions: Upgrade to the correct firmware version
Error code:100001 Meaning:/antiv/signature Illegal Corresponding solutions: Upgrade the latest firmware or burn the card
Error code:100002 Meaning:/antiv/dig/initd.dig Illegal Corresponding solutions:
Error code:100003 Meaning:/antiv/dig/pf_partial.dig Illegal Corresponding solutions:
Error code:PSU Error code Meaning:Reason Corresponding solutions: processing method
Error code:0x0001 Meaning:Input undervoltage Corresponding solutions: Check the power supply
Error code:0x0002 Meaning:Temperature sampling over temperature protection of power radiator Corresponding solutions: Power on again after 10 minutes of power failure. If it occurs again, replace the power supply
Error code:0x0004 Meaning:Temperature sampling over
temperature protection of power radiator
Corresponding solutions:
Error code:0x0008 Meaning:Over temperature protection of environmental emperature sampling in power supply Corresponding solutions:
Error code:0x0010 Meaning:Primary side over current Corresponding solutions: Power on again after 10 minutes of power failure. If it occurs again, replace the power supply
Error code:0x0020 Meaning:Output undervoltage Corresponding solutions: Check the power supply
Error code:0x0040 Meaning:Output over current (continuous load 320A for more than 2S) Corresponding solutions: Tighten the copper bar screw again
Error code:0x0080 Meaning:Primary side over current Corresponding solutions: Power on again after 10 minutes of power failure. If it occurs again, replace the power supply
Error code:0x0100 Meaning:Single circuit overcurrent (protection point 120a) Corresponding solutions: Check the PSU
Error code:0x0200 Meaning:Single circuit overcurrent (protection point 120a) Corresponding solutions:
Error code:0x0400 Meaning:Single circuit overcurrent
(protection point 120a)
Corresponding solutions:
Error code:0x0800 Meaning:Fan failure Corresponding solutions: Replace the PSU
Error code:0x1000 Meaning:Output over current (continuous load of 310A
for more than 5min)
Corresponding solutions: Check the PSU
Error code:0x2000 Meaning:Output over current
(continuous load 295A for
more than 10min)
Corresponding solutions:
Meaning: Corresponding solutions: