240V Mining Circuit & Outlet Quick-Reference Card

NEMA 240V outlets for home mining: amperage, the maximum CONTINUOUS wattage under the NEC/CEC 80% rule, and what each circuit can power. Miners run more efficiently on 240V.

NEMA outletAmperageMax continuous (80% rule)Common useMining note
NEMA 6-1515A2,880 W240V appliance outletOne S19/S21-class miner at 240V (miners run more efficiently on 240V).
NEMA 6-2020A3,840 W240V tools / window ACComfortably powers one S21-class miner at 240V with headroom.
NEMA 6-3030A5,760 W240V heavy applianceOne large hydro miner, or two air miners, on a single 240V circuit.
NEMA 6-5050A9,600 WWelder outletEnough for several miners or a small mining PDU on 240V.
NEMA 14-3030A5,760 WClothes-dryer outlet (4-wire)A very common existing 240V circuit to repurpose for mining — ~5.7 kW usable.
NEMA 14-5050A9,600 WElectric range / EV chargerA common high-capacity outlet; runs a small mining setup or PDU. Don't share with the EV at full load.
NEMA L6-2020A3,840 WLocking 240V connectorTwist-lock 20A/240V — a secure connection that won't pull out, common on mining gear.
NEMA L6-3030A5,760 WLocking 240V connectorTwist-lock 30A/240V — a frequent choice for mining PDUs and rack power.

All rows are 240V. Max continuous wattage applies the NEC/CEC 80% continuous-load rule. Miners run more efficiently on 240V than on 120V. Have a licensed electrician verify your wiring.

Source: D-Central Home-Mining Circuit & Outlet Reference. Max continuous W applies the NEC/CEC 80% rule. Informational only — have a licensed electrician verify your installation.