Whatsminer M50S – Temperature Too High
Critical — Immediate action required
Symptoms
- Auto shutdown from thermal protection
- Red LED flashing
- Hashrate drops before shutdown
Step-by-Step Fix
Power off and cool the unit.
Clean all dust from heatsinks and fans.
Ensure ambient temperature is below 35°C.
Check fan operation and replace failed fans.
Use MinerTool to diagnose per-chip temperatures.
Related Error Codes
Still Having Issues?
Our team of Bitcoin Mining Hackers has been repairing ASIC miners since 2016. We have seen it all and fixed it all. Get a professional diagnosis.