ERR_CHIP_TEMP Warning

Antminer S19 – ASIC Chip Temperature Imbalance

chip temp imbalance detected

Warning — Should be addressed soon

Affected Models: Antminer S19, S19 Pro, S19j Pro

Symptoms

  • Significant temperature variance between chips on same hashboard
  • Some chips running 15°C+ hotter than others
  • Possible hashrate instability

Step-by-Step Fix

1

Power off and inspect the hashboard heatsink mounting.

2

Check if thermal paste coverage is even across all chips.

3

Reapply thermal paste ensuring uniform thin layer on each chip.

4

Verify heatsink is making flat contact — warped heatsinks cause uneven pressure.

5

If one specific chip is consistently hotter, it may be defective and require professional replacement.

When to Seek Professional Repair

If the steps above do not resolve the issue, or if you are not comfortable performing these repairs yourself, professional service is recommended. Attempting advanced repairs without proper equipment can cause further damage.