ERR_TEMP_SENSOR Critical

Antminer S19 – Temp Sensor Failure

temp sensor read failed

Critical — Immediate action required

Affected Models: Antminer S19, S19 Pro, S19j Pro, S19 XP

Symptoms

  • Temperature reads 0°C or -40°C on one hashboard
  • Miner refuses to start hashing on affected board
  • Kernel log shows sensor read errors

Step-by-Step Fix

1

Power off the miner.

2

Reseat the hashboard ribbon cable connections to the control board.

3

Inspect ribbon cables for damage or bent pins.

4

Try swapping hashboard positions to determine if the issue follows the board or the slot.

5

If issue follows the hashboard, the temperature sensor IC on the board is likely damaged and requires professional repair.

When to Seek Professional Repair

If the steps above do not resolve the issue, or if you are not comfortable performing these repairs yourself, professional service is recommended. Attempting advanced repairs without proper equipment can cause further damage.