ASIC Miner – Underpowered PSU Symptoms
Warning — Should be addressed soon
Symptoms
- Hashrate lower than expected
- Frequent restarts
- PSU runs extremely hot
- Voltage sags under load
Step-by-Step Fix
Verify your PSU wattage rating exceeds the miner power draw by at least 10%.
Measure PSU output voltage under load — should not drop below 11.5V.
Check if running on 110V when 220V is required for full power output.
Upgrade to the manufacturer-recommended PSU model for your miner.
Related Error Codes
Still Having Issues?
Our team of Bitcoin Mining Hackers has been repairing ASIC miners since 2016. We have seen it all and fixed it all. Get a professional diagnosis.