Antminer S19k Pro Hyd Repair
The Bitmain Antminer S19k Pro Hyd is the hydro-cooled variant of the popular S19k Pro platform, pairing the efficient BM1366 ASIC chips with liquid cooling to push hashrate beyond what air cooling can sustain. By eliminating fans and using water blocks directly on the hashboards, the S19k Pro Hyd runs quieter and cooler — but introduces hydro-specific failure modes that require specialized repair expertise. D-Central is equipped to handle every aspect of S19k Pro Hyd repair: from chip-level hashboard diagnostics to coolant system pressure testing and corrosion cleanup.
Antminer S19k Pro Hyd Specifications
| Specification | Details |
|---|---|
| Algorithm | SHA-256 |
| Hashrate | 120+ TH/s (varies by configuration) |
| ASIC Chip | BM1366 (BM1366BS / BM1366BP / BM1366AH) |
| Base Platform | Antminer S19k Pro |
| Cooling | Hydro (liquid) cooling |
| Energy Efficiency | ~23 J/TH (base) — improved with liquid thermal headroom |
| Coolant Requirements | Antifreeze pH 7.0–9.0 / Pure water pH 6.5–7.5 / DI water pH 8.5–9.5 |
| Operating Temperature | 20°C – 45°C (coolant inlet) |
Common Antminer S19k Pro Hyd Issues We Repair
Coolant Leaks and Fitting Failures
The hydro cooling loop is the first line of defense for the S19k Pro Hyd — and also its most vulnerable point. Coolant leaks from degraded O-rings, cracked quick-connect fittings, or damaged water blocks can cause catastrophic damage if coolant reaches the hashboard PCB. We pressure-test the entire cooling loop, identify the leak source, replace failed fittings and seals with OEM-spec components, and verify a leak-free system before any electrical testing begins.
Pump and Flow Failures
Inadequate coolant flow leads to thermal throttling or emergency shutdown. Pump motor failures, impeller degradation, air bubbles trapped in the loop, and flow sensor malfunctions are all common culprits. We diagnose the root cause, repair or replace pump assemblies, bleed the loop properly, and verify flow rates meet specification.
Hashboard Corrosion from Coolant Exposure
When coolant chemistry is not maintained within specification, or when a slow leak goes undetected, corrosion attacks solder joints, copper traces, and chip pads on the hashboard. This is the most labor-intensive repair we perform on hydro units. Our technicians clean affected boards under high magnification, repair corroded traces with precision soldering, and replace any BM1366 chips that have been damaged by corrosion or short circuits caused by conductive residue.
ASIC Chip Failures
Even without coolant issues, individual BM1366 chips can fail from voltage stress, thermal cycling, or manufacturing defects. The hydro cooling system can mask thermal issues that would cause shutdown in an air-cooled unit, meaning chip degradation may go unnoticed longer and affect more chips by the time symptoms appear. We perform domain-by-domain testing to identify every failed chip, then replace them with tested OEM-spec BM1366 ICs using precision BGA rework.
Water Block and Thermal Interface Issues
The water blocks that sit directly on the ASIC chips are critical for heat transfer. Degraded thermal compound, uneven mounting pressure, or damaged water block surfaces reduce cooling efficiency even when the pump and coolant are working correctly. We disassemble, clean, and reapply thermal interface material, and inspect water block surfaces for damage or mineral buildup.
Control Board and Sensor Calibration
The S19k Pro Hyd relies on temperature sensors, flow sensors, and pressure sensors to manage the cooling loop. Malfunctioning sensors can cause false alarms, prevent startup, or allow dangerous operating conditions. We test and recalibrate all sensors, reflash firmware, and repair or replace control board components as needed.
Our Hydro Miner Repair Process
- Intake & Coolant Drain — We safely drain the cooling loop, test coolant pH and condition, and log the unit serial number and reported symptoms.
- Cooling System Inspection — Full pressure test of the loop, visual inspection of all fittings, water blocks, and hoses. Any leaks are identified and documented.
- Electrical Diagnostic — Hashboard detection, domain-level chip testing, voltage rail measurement, and control board verification.
- Transparent Quote — Detailed breakdown of all failures found, with repair costs and timeframe. We recommend against repair when costs exceed the economic value of the unit.
- Component-Level Repair — Cooling system: fitting replacement, O-ring renewal, water block service. Electronics: chip replacement, trace repair, connector resoldering, thermal compound reapplication.
- Reassembly & Burn-In — Fresh coolant fill (verified chemistry), flow test, leak test under pressure, and extended burn-in under full hash load to verify stable performance and zero leaks.
- Return Shipping — Unit ships back drained, sealed, fully documented with repair details.
Repair Pricing
Hydro-cooled miner repairs involve both cooling system and electronics work, so pricing depends on the combination of failures. A straightforward fitting replacement is far less than a multi-board corrosion cleanup with chip replacements. For an estimate tailored to your situation, use our ASIC Repair Cost Estimator or contact us directly with photos and a description of the symptoms.
Why D-Central for Your S19k Pro Hyd Repair
Hydro-cooled ASIC repair sits at the intersection of precision electronics and fluid systems engineering. Most repair shops handle one or the other — D-Central handles both. Since 2016, we have been the Bitcoin Mining Hackers: taking complex mining hardware apart, understanding it at the deepest level, and putting it back together better than before. Our Laval, Quebec repair facility is stocked with BM1366 chips, hydro fittings, O-ring kits, pump components, thermal compound, and every part your S19k Pro Hyd needs. We serve miners across Canada, the United States, and internationally with transparent pricing and honest assessments.
Frequently Asked Questions
How long does an S19k Pro Hyd repair take?
Expect 7–14 business days for most hydro miner repairs. Simple cooling system fixes (fitting replacement, O-ring swap) can be faster. Complex repairs involving corrosion cleanup and multiple chip replacements across hashboards may take up to three weeks.
My S19k Pro Hyd is leaking — should I keep running it?
No. Power down the unit immediately. Running a miner with an active coolant leak risks destroying hashboards and the control board. The faster you shut it down, the less damage occurs and the lower the repair cost. Drain what coolant you can, and ship it to us.
Can you repair hashboards that were submerged in coolant?
In many cases, yes. The repairability depends on how long the board was exposed, whether it was powered during the leak, and the type of coolant used. Boards powered while wet sustain significantly more damage. We assess each board individually and only proceed when repair is economically justified.
What coolant do you recommend?
Use manufacturer-specified coolant and maintain proper pH levels: antifreeze at pH 7.0–9.0, pure water at pH 6.5–7.5, or deionized water at pH 8.5–9.5. Avoid tap water entirely — mineral content causes scale and corrosion. Test pH monthly and replace coolant at least annually.
Is the S19k Pro Hyd the same hashboard as the air-cooled S19k Pro?
The hashboards share the same BM1366 chip platform, but the hydro version has water blocks mounted directly on the chips instead of heatsinks and fans. The board layout and electrical design are similar, but the cooling interface and some connector configurations differ. Repair procedures overlap significantly, but the hydro version requires additional cooling system work.
Can I convert my S19k Pro Hyd back to air cooling?
Technically possible with aftermarket conversion kits, but it typically means running at lower hashrates due to reduced thermal headroom. Contact us to discuss your specific situation — we can advise whether conversion or hydro system repair makes more sense for your operation.
How should I ship a hydro-cooled miner?
Drain all coolant completely, cap every fitting to prevent contamination and moisture ingress, and pack the unit securely in its original box or equivalent heavy-duty packaging. Include a description of the issue and your contact information. Ship to our Laval, Quebec facility.
Do you warranty hydro miner repairs?
Yes. All D-Central repairs — including hydro-specific cooling system work — come with a post-repair warranty. If the repaired component fails within the warranty period, we fix it again at no charge.
Get Your S19k Pro Hyd Back Online
Hydro-cooled miners are serious hardware investments, and every day offline is significant hashrate and revenue lost. Whether your S19k Pro Hyd has a leaking fitting, a dead pump, or corrosion-damaged hashboards, D-Central’s specialized repair team can bring it back to full performance. Contact us today to start your repair, or use our ASIC Repair Cost Estimator for a quick ballpark quote.
How long does an S19k Pro Hyd repair take?
Expect 7–14 business days for most hydro miner repairs. Simple cooling system fixes (fitting replacement, O-ring swap) can be faster. Complex repairs involving corrosion cleanup and multiple chip replacements across hashboards may take up to three weeks.
My S19k Pro Hyd is leaking — should I keep running it?
No. Power down the unit immediately. Running a miner with an active coolant leak risks destroying hashboards and the control board. The faster you shut it down, the less damage occurs and the lower the repair cost. Drain what coolant you can, and ship it to us.
Can you repair hashboards that were submerged in coolant?
In many cases, yes. The repairability depends on how long the board was exposed, whether it was powered during the leak, and the type of coolant used. Boards powered while wet sustain significantly more damage. We assess each board individually and only proceed when repair is economically justified.
What coolant do you recommend?
Use manufacturer-specified coolant and maintain proper pH levels: antifreeze at pH 7.0–9.0, pure water at pH 6.5–7.5, or deionized water at pH 8.5–9.5. Avoid tap water entirely — mineral content causes scale and corrosion. Test pH monthly and replace coolant at least annually.
Is the S19k Pro Hyd the same hashboard as the air-cooled S19k Pro?
The hashboards share the same BM1366 chip platform, but the hydro version has water blocks mounted directly on the chips instead of heatsinks and fans. The board layout and electrical design are similar, but the cooling interface and some connector configurations differ. Repair procedures overlap significantly, but the hydro version requires additional cooling system work.
Can I convert my S19k Pro Hyd back to air cooling?
Technically possible with aftermarket conversion kits, but it typically means running at lower hashrates due to reduced thermal headroom. Contact us to discuss your specific situation — we can advise whether conversion or hydro system repair makes more sense for your operation.
How should I ship a hydro-cooled miner?
Drain all coolant completely, cap every fitting to prevent contamination and moisture ingress, and pack the unit securely in its original box or equivalent heavy-duty packaging. Include a description of the issue and your contact information. Ship to our Laval, Quebec facility.
Do you warranty hydro miner repairs?
Yes. All D-Central repairs — including hydro-specific cooling system work — come with a post-repair warranty. If the repaired component fails within the warranty period, we fix it again at no charge.