Understanding the specific operating temperature ranges of your miners is crucial for ensuring their efficient and prolonged functionality. These values refer to the intake air temperature, which may vary from the ambient room temperature due to factors such as dust accumulation.
When needed, please clean your miner to maintain optimal intake air temperature. Refer to our guide on miner maintenance and dust removal for more information.
All our ANTMINER models have a built-in protection program that automatically shuts down the miner if the temperature exceeds the allowable range. For more details on high-temperature alerts and protection measures, please refer to our dedicated guide.
Here are the maximum operating temperatures, measured in degrees Celsius, for various ANTMINER models:
Model | Max PCB Temp (°C) | Max Chip Temp (°C) |
---|---|---|
E9 | 80 | – |
L7 | 80 | – |
S19XP | 75 | – |
S19a Pro | 80 | – |
S19a | 80 | – |
S19j | 85 | – |
S19j Pro | 85 | – |
S19 Pro | 80 | – |
S19 | 80 | – |
T19 | 80 | – |
Z15/Z15j/Z15e | 80 | – |
S17e/T17e/S17+ | 80 | – |
T17+ | 75 | – |
S17/S17 Pro/T17 | 75 | – |
S15 | 80 | – |
T15 | 80 | – |
S11 | 95 | – |
Z9MINI | 80 | 125 |
Z9 | 80 | – |
V9 | 80 | – |
S9 | 90 | 135 |
S9I | 85 | – |
S9j和S9-Hydro | 95 | – |
T9 | 90 | 135 |
T9+ | 95 | 125 |
S9 SE/S9k | 85 | – |
B7 | 75 | – |
K5 | 80 | – |
D5 | 85 | – |
DR3和DR5 | 85 | – |
E3 | 65 | – |
L3+和L3++ | 90 | – |
D3 | 85 | – |
A3 | 85 | 115 |
X3 | 80 | 127 |
B3 | 80 | 127 |
If your miner’s temperatures are continually increasing and nearing these limits, please contact us immediately for technical assistance and advice on managing high temperatures.