The Antminer S21 XP Hyd is Bitmain’s answer to a question every serious Bitcoin miner has asked: Comment do you push SHA-256 efficiency to the absolute edge without burning down your facility? The answer is refroidissement hydro, BM1370 chips, and 473 TH/s of raw puissance de hashage packed into a unit smaller than most refroidi par air miners half its performance.
chez D-Central Technologies, we have been tearing apart, rebuilding, and deploying Antminers since 2016. We have seen every generation from the S9 to the S21 Pro. The S21 XP Hyd represents something different: it is the first refroidi par eau unit that makes genuine economic sense for small-to-mid-scale operators, not just industrial farms with unlimited capital. Voici notre évaluation complète et sans détour.
Antminer S21 XP Hyd: Spécifications complètes
Before we get into the nuances, Voici tout ce que vous devez savoir at a glance. These are the official Bitmain Spécifications, verified against our own benchmarks.
| Spécification | Valeur |
|---|---|
| Modèle | Antminer S21 XP Hyd |
| Algorithme | SHA-256 (Bitcoin, Bitcoin Cash, BSV) |
| Hashrate | 473 TH/s (±3%) |
| Inconvénientsommation électrique | 5,676W (±5%) |
| efficacité énergétique | 12.0 J/TH |
| Puce ASIC | BM1370 |
| Nombre de puces | 324 (108 per hashboard × 3 hashboards) |
| Refroidissement | Hydro (liquid-to-chip water Refroidissement) |
| Coolant Flow Rate | 8.0–10.0 L/min |
| Coolant Pressure | ≤3.5 bar |
| Recommended Coolant | Deionized water, pure water, or antifreeze |
| Entrée d’alimentation | 3-phase 380–415V AC (industrial) |
| Dimensions | 410 × 170 × 209 mm |
| Poids | 12.8–16 kg |
| Niveau sonore | ~50 dB (significantly quieter than refroidi par air) |
| Température de fonctionnement | 5–45°C |
| Humidity | 5–95% (non-condensing) |
| Interface réseau | Ethernet (RJ45) |
| Garantie | 365 days |
| Date de sortie | October 2024 |
The numbers that matter most: 473 TH/s at 12 J/TH. To put that in perspective, the original Antminer S21 shipped at 200 TH/s with 17.5 J/TH. The XP Hyd delivers 2.36x the hashrate at 31% better efficiency. That is not incremental improvement — that is a generational leap.
Architecture Deep Dive: BM1370 Chips and refroidissement hydro
The BM1370 Puce ASIC
The heart of the S21 XP Hyd is the BM1370, Bitmain’s latest-generation SHA-256 Puce ASIC. Each BM1370 delivers over 1.2 TH/s per chip — a substantial improvement over the BM1368 (700+ GH/s per chip) used in the standard S21 and S21 Hyd, and a massive leap from the BM1366 (500 GH/s per chip) in the S19 XP series.
With 324 BM1370 chips distributed across three hashboards (108 chips each), the S21 XP Hyd achieves its 473 TH/s target through sheer density and per-chip efficiency. The BM1370 runs on a refined process node that enables lower voltage operation per transistor, which translates directly into the 12 J/TH wall efficiency Note. For a deeper technical breakdown of Bitmain’s chip evolution, Inconvénientsultez notre Complete Guide to Bitcoin Puce ASIC Evolution: BM1385 to BM1370.
Three hashboard Configuration
The unit houses three independent hashboards, each carrying 108 BM1370 chips. This modular architecture is critical for serviceability. If a single hashboard fails, you can isolate and replace it without downing the entire unit — something that matters enormously when you are running at nearly half a petahash per machine. If you ever need au niveau des cartes repair, D-Central’s Antminer S21 XP repair service handles these at the component level.
Intégrée Water Block Design
Unlike refroidi par air units that rely on heatsinks and high-speed fans to dissipate heat, the S21 XP Hyd uses a direct liquid-to-chip cold plate Intégrée onto each hashboard. Coolant flows directly over machined copper or aluminum water blocks that make contact with the ASIC packages. The Résultat is dramatically more efficient thermal transfer compared to air Refroidissement — liquid has roughly 25x the thermal conductivity of air.
This is what allows Bitmain to push the BM1370 chips harder while maintaining lower junction temperatures, which extends chip lifespan and reduces étranglement thermique to near zero under proper opeNote conditions.
refroidissement hydro Explained: What You Actually Need
If you have only ever run refroidi par air ASICs, refroidissement hydro introduces a new infrastructure layer. Here is exactly Qu’est-ce que involved.
Comment the Water Loop Works
The S21 XP Hyd connects to an Externe Coolant Distribution Unit (CDU) via quick-connect water fittings. Hot coolant exits the miner, flows to the CDU where the heat is rejected (typically via a radiator, dry cooler, or heat exchanger), and the cooled liquid is pumped back through the miner in a closed loop.
The system requires:
- Coolant flow rate: 8.0–10.0 L/min per unit
- Maximum coolant pressure: ≤3.5 bar
- Inlet coolant temperature: Ideally 20–35°C for optimal hashrate stability
- Approved coolants: Deionized water, purified water, or glycol-based antifreeze (critical for cold climates like Canada)
CDU (Coolant Distribution Unit) Requirements
The CDU is the Externe system that manages coolant circulation and heat rejection. You have several options:
- Bitmain’s OEM CDU: Purpose-built for their Hyd series, handles multiple units in a rack
- tiers CDUs: Industrial refroidissement liquide distribution units from companies like CoolIT, GRC, or custom-built systems
- DIY heat exchanger Installation: For smaller deployments, a high-flow pump, reservoir, and radiator/dry cooler can work — but this requires careful engineering
The key Métrique is thermal rejection capacity. The S21 XP Hyd produces roughly 5,676W of heat. Your CDU and heat rejection system must handle at least that much thermal load per unit, with headroom for Temp. ambianteerature variations. Planning to run 10 units? You need 56+ kW of Refroidissement capacity.
Coolant Chemistry Matters
This is where operators get burned. Tap water will corrode your water blocks within months. Always use:
- Deionized (DI) water with a biocide additive to prevent algae and bacterial growth
- Propylene glycol antifreeze mix (30–50% concentration) if your facility operates in sub-zero Temp. ambianteeratures — essential for Canadian operations
- pH monitoring: Maintain coolant pH between 7.0–8.5
- Filtration: Inline particulate filters to prevent sediment from clogging water block micro-channels
Pour en savoir plus on refroidissement liquide fundamentals and Comment set up a proper Refroidissement loop, Inconvénientsultez notre Immersion Refroidissement for Home Bitcoin Miners guide. While immersion and refroidissement hydro are different technologies, the coolant management principles overlap significantly.
Performance en conditions réelles Analysis
Hashrate Inconvénientsistency
Lors de nos tests and deployment experience, the S21 XP Hyd Inconvénientsistently hits between 460–480 TH/s depending on coolant inlet temperature. With coolant at 25°C inlet, the unit stabilizes around 473 TH/s — right at the rated spec. Push inlet temperature to 35°C and you may see slight deNote to around 460 TH/s. Keep it below 20°C (very achievable in Canadian winters) and you can sometimes see the unit hold steady at 478–480 TH/s.
This stability is the hydro advantage. refroidi par air units are sensitive to Temp. ambianteerature, dust accumulation, and fan degradation. The S21 XP Hyd maintains a near-flat hashrate curve as long as coolant flow and temperature are within spec.
Inconvénientsommation électrique Accuracy
Bitmain rates the S21 XP Hyd at 5,676W ±5% at the wall. En pratique, we have measured between 5,500W and 5,900W depending on hashrate Variance and Tension d’entrée stability. The 12 J/TH efficiency figure holds up under real-world conditions — a remarkable achievement for any ASIC at this hashrate tier.
Note that this power figure does not include CDU Inconvénientsommation électrique. Your pumps, fans (for dry coolers/radiators), and control systems will add 5–15% to total system Inconvénientsommation électrique depending on your Refroidissement infrastructure. Budget 6,000–6,500W total system power per unit for realistic planning.
Thermal Performance
Chip junction temperatures typically stay between 55–70°C with properly conditioned coolant — dramatically cooler than the 80–95°C range common on refroidi par air units running at maximum. Cooler chips mean longer lifespans, fewer thermal cycling failures, and more Inconvénientsistent hash delivery over years of operation.
Infrastructure Requirements
The S21 XP Hyd is not a plug-and-play device. It demands purpose-built infrastructure. Here is a realistic breakdown of what you need.
Electrical
- Entrée d’alimentation: 3-phase 380–415V AC (industrial power). This is NOT a 240V/single-phase machine
- Per-unit current draw: Approximately 8.6A per phase at 380V
- Circuit protection: Dedicated breakers with appropriate amperage Note per unit
- PDU requirements: Industrial-grade power distribution with per-outlet monitoring recommended
- Total system power (with CDU): Budget 6,000–6,500W per unit
Plumbing
- Quick-connect fittings: Compatible with Bitmain’s Hyd series connectors
- Manifold system: For multi-unit deployments, a supply/return manifold with ball valves for each unit allows individual isolation
- Pressure testing: Leak-test your entire loop at 1.5x opeNote pressure before powering on any units
- Drain points: Install low-point drains for maintenance and winterization
Refroidissement Infrastructure
- Dry cooler / radiator: Sized for total thermal load plus 20% headroom
- Pump: High-flow industrial pump capable of 8–10 L/min per unit at required pressure head
- Reservoir: Sufficient coolant volume to maintain stable temperatures during transient loads
- Temperature monitoring: Inlet and outlet temperature sensors with alerting
Environment
- Space: The unit itself is compact (410 × 170 × 209 mm), but you need space for the CDU, plumbing runs, and electrical distribution
- Ventilation: Minimal compared to refroidi par air — the heat goes into the coolant, not the room air
- Leak detection: Water leak sensors under every unit and along plumbing runs. Non-negotiable
Bruit Comparaison: The Hydro Advantage
This is where the S21 XP Hyd earns its keep for operators who care about their environment and their hearing.
| Miner | Niveau sonore | Contexte |
|---|---|---|
| S21 XP Hyd | ~50 dB | Comparable to a quiet conversation or modern refrigerator |
| S21 XP (refroidi par air) | ~76 dB | Comparable to a vacuum cleaner or busy street traffic |
| S21 Pro (refroidi par air) | ~75 dB | Similar to the S21 XP refroidi par air |
| Whatsminer M63S | ~50 dB (hydro) | Comparable to S21 XP Hyd |
The difference between 50 dB and 76 dB is not incremental — it is perceived as roughly 6x louder to the human ear (every 10 dB represents a doubling of perceived loudness). The S21 XP Hyd can operate in an adjacent room without hearing protection. The refroidi par air S21 XP absolutely cannot.
Note that 50 dB is the miner unit itself. Your CDU pumps and dry cooler fans will add Bruit to the overall system, typically 40–60 dB depending on the equipment. Still dramatically quieter than a room full of screaming refroidi par air ASICs. Pour en savoir plus on managing mining Bruit, check our ASIC Bruit Reduction Guide.
Analyse de rentabilité: Running the Numbers
Profitability is the only Métrique that matters for most operators. Here is a transparent breakdown at various tarifs d’électricité using February 2026 network conditions (difficulty ~110T, BTC Prix ~$96,000, récompense de bloc 3.125 BTC).
| tarif d’électricité | Revenu quotidien | Coût électrique quotidien | Profit quotidien | Profit mensuel | Profit annuel |
|---|---|---|---|---|---|
| $0.04/kWh (cheap hydro/industrial) | $17.01 | $5.45 | $11.56 | $346.80 | $4,219.40 |
| $0.06/kWh (competitive rate) | $17.01 | $8.17 | $8.84 | $265.20 | $3,226.60 |
| $0.07/kWh (good residential) | $17.01 | $9.54 | $7.47 | $224.10 | $2,726.55 |
| $0.10/kWh (Moyenne North American) | $17.01 | $13.62 | $3.39 | $101.70 | $1,237.35 |
| $0.12/kWh (above Moyenne) | $17.01 | $16.35 | $0.66 | $19.80 | $240.90 |
| $0.15/kWh (expensive residential) | $17.01 | $20.43 | -$3.42 | -$102.60 | -$1,248.30 |
Critical Notes on these numbers:
- Revenue figures are based on current difficulté du réseau and BTC Prix. Both fluctuate significantly
- Power costs above do not include CDU/Refroidissement infrastructure power. Add 5–15% to the power cost column for realistic total system economics
- Hardware acquisition cost (typically $6,000–$10,000 depending on market conditions) is not factored into Profit quotidien — ROI at $0.07/kWh is approximately 2.5–3 years
- Canadian miners with hydroelectric rates in the $0.04–$0.06/kWh range are in the sweet spot for this machine
The breakeven tarif d’électricité (where revenue equals power cost alone) sits around $0.125/kWh. Factor in CDU power and infrastructure amortization, and the real breakeven is closer to $0.11/kWh. If your all-in tarif d’électricité is above that, this machine does not make economic sense unless you are capturing and monetizing the chaleur résiduelle. For a full profitability deep dive, Inconvénientsultez notre Is minage Bitcoin Profitable in 2026? analysis.
Comparaison: S21 XP Hyd vs. S21 XP vs. S21 Pro vs. Whatsminer M63S
Contexte matters. Voici comment the S21 XP Hyd stacks up against the alternatives that miners are actually choosing between.
| Spécification | S21 XP Hyd | S21 XP (Air) | S21 Pro (Air) | Whatsminer M63S (Hydro) |
|---|---|---|---|---|
| Hashrate | 473 TH/s | 270 TH/s | 234 TH/s | 390–416 TH/s |
| Power | 5,676W | 3,645W | 3,510W | 7,215–7,700W |
| Efficiency | 12.0 J/TH | 13.5 J/TH | 15.0 J/TH | 18.5 J/TH |
| Refroidissement | Hydro | Air (4 fans) | Air (4 fans) | Hydro |
| Bruit | ~50 dB | ~76 dB | ~75 dB | ~50 dB |
| Dimensions | 410x170x209mm | 449x219x293mm | 450x219x293mm | Larger form factor |
| Poids | ~13–16 kg | ~18.7 kg | ~18.5 kg | ~27.5 kg |
| Entrée d’alimentation | 380–415V 3-phase | 220–277V | 220–277V | 380V 3-phase |
| Garantie | 365 days | 365 days | 365 days | 180 days |
S21 XP Hyd vs. S21 XP (refroidi par air)
Same chip generation, radically different deployment. The Hyd variant delivers 75% more hashrate and 11% better efficiency than its refroidi par air sibling. The tradeoff is infrastructure complexity: the refroidi par air S21 XP runs on standard 220–277V single-phase power and needs nothing but electricity and internet. The Hyd requires a complete water Refroidissement infrastructure.
For operators who already have or are building hydro infrastructure, the XP Hyd is the obvious choice: more hash per rack unit, better efficiency, dramatically less Bruit. For operators adding a few machines to an existing refroidi par air facility, the refroidi par air S21 XP at 13.5 J/TH is still excellent.
S21 XP Hyd vs. S21 Pro (refroidi par air)
The S21 Pro is the workhorse of refroidi par air Antminers right now at 234 TH/s and 15 J/TH. The XP Hyd doubles the hashrate and improves efficiency by 20%. But the Pro costs significantly less per unit and requires zero plumbing. For mineurs domestiques and small operators, the S21 Pro remains the practical choice. For facilities scaling beyond 5–10 PH/s, the XP Hyd’s density and efficiency Avantages compound into meaningful operational savings.
S21 XP Hyd vs. Whatsminer M63S (Hydro)
This is the head-to-head that matters for hydro operators. The S21 XP Hyd dominates on efficiency: 12 J/TH vs. 18.5 J/TH. That is a 35% efficiency advantage — meaning the M63S burns 35% more electricity per terahash. The S21 XP Hyd also delivers more hashrate (473 vs. ~410 TH/s) while Inconvénientsuming less power (5,676W vs. 7,215W). The M63S weighs almost twice as much and comes with only a 180-day Garantie versus Bitmain’s 365-day coverage.
The only scenario favoring the M63S is Prix: if you can acquire M63S units at a deep discount, the lower acquisition cost might offset the efficiency gap. But on a $/TH/day basis, the S21 XP Hyd wins convincingly.
For a broader Comparaison of top matériel de minage, Inconvénientsultez notre Best Bitcoin Miners 2026 guide.
récupération de chaleur: The chauffage d’appoint Potential
Here is where the S21 XP Hyd becomes genuinely exciting for the Mining Hacker community: water-cooled récupération de chaleur is the premium tier of à double usage mining.
refroidi par air miners dump heat into room air, which is fine for space heating but difficult to direct precisely. The S21 XP Hyd puts all 5,676W of thermal energy directly into a water loop. That heated water can be routed through:
- Radiant floor heating: Hot water from the miner’s return loop Fraisds directly into hydronic floor heating systems
- Domestic hot water preheat: A heat exchanger transfers mining heat to your domestic hot water tank, reducing water heating costs
- Greenhouse heating: Closed-loop water heating for year-round growing in cold climates
- Pool/hot tub heating: Direct or heat-exchanged transfer to recreational water Caractéristiques
- Workshop/garage heating: Hydronic fan coils convert the heated water back to warm air in specific zones
At 5,676W of continuous thermal output, a single S21 XP Hyd produces approximately 19,370 BTU/hour — equivalent to a decent-sized portable chauffage d’appoint running at maximum. In a Canadian winter, this meaningfully offsets heating costs while simultaneously mining Bitcoin. The economics shift dramatically: that $7–$12/day in mining profit plus $5–$10/day in displaced heating costs means the machine is effectively geneNote $12–$22/day of total Valeur.
This is exactly the à double usage mining philosophy we champion at D-Central. To explore this further, Inconvénientsultez notre Bitcoin chauffages d’appoint page and the minage Bitcoin récupération de chaleur: 25+ Real-World Applications guide.
Qui devrait acheter the S21 XP Hyd?
Acheteurs idéaux
- Small-to-mid mining facilities (1–50 PH/s) building out purpose-built infrastructure with refroidissement hydro from the start
- Operators upgrading from older hydro units (S19 Hyd, S19 XP Hyd) who already have water Refroidissement infrastructure in place
- Canadian miners with access to cheap hydroelectric power ($0.04–$0.07/kWh) and cold Temp. ambianteeratures for efficient heat rejection
- récupération de chaleur enthusiasts building Intégrée mining/heating systems where the water loop serves double duty
- Bruit-sensitive deployments where refroidi par air ASICs are not an option due to Bruit restrictions
Pas idéal pour
- mineurs domestiques without existing hydro infrastructure — the cost of building a water Refroidissement loop from scratch for 1–2 units rarely makes economic sense. Look at the Antminer S21 (refroidi par air) instead
- Operators paying above $0.11/kWh — the math does not work without récupération de chaleur Valeur
- First-time miners — if you are just starting out, build operational knowledge with refroidi par air units first. Inconvénientsultez notre Comment Start minage Bitcoin guide
- Facilities with only single-phase 240V power — the S21 XP Hyd requires 3-phase industrial power
Maintenance and Long-Term Reliability
Routine Maintenance
- Coolant quality checks: Test pH, conductivity, and particulate levels monthly
- Coolant replacement: Every 6–12 months depending on chemistry and filtration quality
- Filter replacement: Inline filters should be changed when pressure differential exceeds spec
- Leak inspection: Visual inspection of fittings and connections weekly
- firmware updates: Keep firmware current for hashrate optimization and security patches
Common Failure Modes
- Coolant contamination: The #1 cause of hydro unit failures. Poor water quality corrodes water blocks and clogs micro-channels
- Fitting leaks: Quick-connect fittings can develop leaks from repeated connection/disconnection or thermal cycling
- hashboard failure: Same as refroidi par air units — individual Puce ASIC failures can take down a hashboard
- carte de contrôle issues: Rare but possible, same as any Antminer generation
When repairs are needed, D-Central’s ASIC Repair service handles hydro units with full component-level diagnostic capability. We have been repairing Antminers since the S9 era and have specific tooling and expertise for the hydro series. Our S21 XP repair page Détails the specific services available for this Modèle.
Should You Wait for the S21 XP+ Hyd?
Bitmain has announced the S21 XP+ Hyd, shipping mid-2025, with 500 TH/s at 11 J/TH. That is a 5.7% hashrate bump and 8.3% efficiency improvement over the standard XP Hyd. Worth waiting for?
If you are still in the infrastructure planning phase, waiting for the XP+ Hyd makes sense. If your facility is built and ready, every day without hashing is lost revenue. At current difficulté du réseau and BTC Prix, the S21 XP Hyd generates positive ROI from day one (at competitive tarifs d’électricité). Mining is a time-sensitive business — the difficulty adjustment waits for no one.
The XP+ also typically commands a premium at launch. The original XP Hyd may see Prix reductions as the newer Modèle ships, creating a potential buying opportunity for budget-Inconvénientscious operators.
Verdict: The S21 XP Hyd Earns Its Place
The Antminer S21 XP Hyd is not for everyone, and it does not pretend to be. It is a specialized, high-performance machine that demands purpose-built infrastructure and operational competence. But for the operators who meet those requirements, it delivers:
- Industry-leading efficiency at 12 J/TH among refroidi par eau miners
- Massive hashrate density — 473 TH/s in a compact, lightPoids package
- Operational quiet at ~50 dB, enabling deployments impossible with refroidi par air units
- Premium récupération de chaleur potential via the Intégrée water loop
- Bitmain’s 365-day Garantie and the backing of the largest ASIC manufacturer in the world
For Canadian miners with hydroelectric power and cold winters, this machine is almost purpose-built for your conditions: cheap electricity, efficient heat rejection through cold ambient, and a water loop that can double as home heating infrastructure. That is the Mining Hacker playbook in action — taking institutional-grade hardware and making it work for your sovereign operation.
chez D-Central Technologies, we stock, deploy, and repair the full Antminer lineup including the S21 XP Hyd. Whether you are planning your first refroidi par eau build or scaling an existing operation, contact our team for hardware sourcing, deployment Inconvénientsulting, and ongoing repair support.
Foire aux questions
Qu’est-ce que the hashrate of the Antminer S21 XP Hyd?
The Antminer S21 XP Hyd delivers 473 TH/s (±3%) using Bitmain’s BM1370 Puce ASICs. It is currently one of the highest-hashrate single-unit Bitcoin miners available, second only to the newer S21 XP+ Hyd (500 TH/s) and the rack-scale S21e XP Hyd 3U (860 TH/s).
Comment efficient is the S21 XP Hyd compared to refroidi par air Antminers?
At 12 J/TH, the S21 XP Hyd is 11% more efficient than the refroidi par air S21 XP (13.5 J/TH) and 20% more efficient than the S21 Pro (15 J/TH). refroidissement hydro enables lower Temp. puceeratures, which allows the BM1370 chips to operate at higher frequencies with less power waste.
Can I run the S21 XP Hyd on standard 240V home power?
No. The S21 XP Hyd requires 3-phase 380–415V AC power, which is industrial-grade electrical service. Standard North American residential power (120V/240V single-phase) will not work. You need either an industrial facility, a commercial space with 3-phase service, or a properly permitted electrical upgrade.
Comment loud is the S21 XP Hyd?
The miner itself operates at approximately 50 dB, roughly equivalent to a quiet conversation or a modern refrigerator. This is dramatically quieter than refroidi par air Antminers which operate at 75–80 dB. Commentever, your total system Bruit will also include CDU pumps and Externe heat rejection fans.
What coolant should I use in the S21 XP Hyd?
Bitmain recommends deionized water, purified water, or glycol-based antifreeze. Never use tap water — minerals and contaminants will corrode the internal water blocks. For cold-climate operations (like Canada), a 30–50% propylene glycol antifreeze mix is recommended to prevent freezing damage during shutdowns.
Comment profitable is the S21 XP Hyd in 2026?
At $0.07/kWh electricity, the S21 XP Hyd generates approximately $7.47/day in profit (before CDU power costs), or roughly $2,700/year. At $0.04/kWh (cheap hydro power), Profit quotidien rises to approximately $11.56. Profitability depends heavily on Bitcoin Prix, difficulté du réseau, and your tarif d’électricité. Inconvénientsultez notre Analyse de rentabilité for current calculations.
Can the S21 XP Hyd be used as a water heater or chauffage d’appoint?
Absolutely — and this is one of its strongest use cases. The 5,676W of thermal energy goes directly into the water loop, producing approximately 19,370 BTU/hour. This heated water can Fraisd radiant floor heating, domestic hot water preheating, greenhouse heating, or hydronic fan coils. The récupération de chaleur potential is significantly better than refroidi par air miners because you have precise control over where the heat goes. Visitez notre Bitcoin chauffages d’appoint page Pour en savoir plus on à double usage mining.
What happens if the water Refroidissement system leaks?
A coolant leak can damage the miner and surrounding equipment. This is Pourquoi leak detection sensors are mandatory for any hydro deployment. Best practices include: water leak sensors under every unit, drip trays beneath all plumbing connections, automatic pump shutoff on leak detection, and regular visual inspection of fittings. Properly maintained systems with quality fittings rarely leak, but preparation is essential.
Comment does the S21 XP Hyd compare to the Whatsminer M63S?
The S21 XP Hyd significantly outperforms the M63S in efficiency (12 J/TH vs. 18.5 J/TH), hashrate (473 vs. ~410 TH/s), and Inconvénientsommation électrique (5,676W vs. 7,215W). The M63S is heavier, less efficient, and comes with a shorter Garantie (180 days vs. 365 days). The only advantage of the M63S would be a significantly lower purchase Prix, which occasionally occurs in the secondary market.
Where can I get the S21 XP Hyd repaired?
D-Central Technologies provides full component-level repair for the entire Antminer S21 series, including the XP Hyd variant. Our S21 XP repair service covers hashboard diagnostics, chip replacement, water block inspection, carte de contrôle repair, and full-unit testing. As Canada’s largest ASIC repair center, we have handled thousands of Antminer repairs since 2016.
What is the hashrate of the Antminer S21 XP Hyd?
The Antminer S21 XP Hyd delivers 473 TH/s (±3%) using Bitmain’s BM1370 ASIC chips. It is currently one of the highest-hashrate single-unit Bitcoin miners available, second only to the newer S21 XP+ Hyd (500 TH/s) and the rack-scale S21e XP Hyd 3U (860 TH/s).
How efficient is the S21 XP Hyd compared to air-cooled Antminers?
At 12 J/TH, the S21 XP Hyd is 11% more efficient than the air-cooled S21 XP (13.5 J/TH) and 20% more efficient than the S21 Pro (15 J/TH). Hydro cooling enables lower chip temperatures, which allows the BM1370 chips to operate at higher frequencies with less power waste.
Can I run the S21 XP Hyd on standard 240V home power?
No. The S21 XP Hyd requires 3-phase 380–415V AC power, which is industrial-grade electrical service. Standard North American residential power (120V/240V single-phase) will not work. You need either an industrial facility, a commercial space with 3-phase service, or a properly permitted electrical upgrade.
How loud is the S21 XP Hyd?
The miner itself operates at approximately 50 dB, roughly equivalent to a quiet conversation or a modern refrigerator. This is dramatically quieter than air-cooled Antminers which operate at 75–80 dB. However, your total system noise will also include CDU pumps and external heat rejection fans.
What coolant should I use in the S21 XP Hyd?
Bitmain recommends deionized water, purified water, or glycol-based antifreeze. Never use tap water — minerals and contaminants will corrode the internal water blocks. For cold-climate operations (like Canada), a 30–50% propylene glycol antifreeze mix is recommended to prevent freezing damage during shutdowns.
How profitable is the S21 XP Hyd in 2026?
At $0.07/kWh electricity, the S21 XP Hyd generates approximately $7.47/day in profit (before CDU power costs), or roughly $2,700/year. At $0.04/kWh (cheap hydro power), daily profit rises to approximately $11.56. Profitability depends heavily on Bitcoin price, network difficulty, and your electricity rate. See our profitability analysis for current calculations.
Can the S21 XP Hyd be used as a water heater or space heater?
Absolutely — and this is one of its strongest use cases. The 5,676W of thermal energy goes directly into the water loop, producing approximately 19,370 BTU/hour. This heated water can feed radiant floor heating, domestic hot water preheating, greenhouse heating, or hydronic fan coils. The heat recovery potential is significantly better than air-cooled miners because you have precise control over where the heat goes. Visit our Bitcoin Space Heaters page for more on dual-purpose mining.
What happens if the water cooling system leaks?
A coolant leak can damage the miner and surrounding equipment. This is why leak detection sensors are mandatory for any hydro deployment. Best practices include: water leak sensors under every unit, drip trays beneath all plumbing connections, automatic pump shutoff on leak detection, and regular visual inspection of fittings. Properly maintained systems with quality fittings rarely leak, but preparation is essential.
How does the S21 XP Hyd compare to the Whatsminer M63S?
The S21 XP Hyd significantly outperforms the M63S in efficiency (12 J/TH vs. 18.5 J/TH), hashrate (473 vs. ~410 TH/s), and power consumption (5,676W vs. 7,215W). The M63S is heavier, less efficient, and comes with a shorter warranty (180 days vs. 365 days). The only advantage of the M63S would be a significantly lower purchase price, which occasionally occurs in the secondary market.
Where can I get the S21 XP Hyd repaired?
D-Central Technologies provides full component-level repair for the entire Antminer S21 series, including the XP Hyd variant. Our S21 XP repair service covers hashboard diagnostics, chip replacement, water block inspection, control board repair, and full-unit testing. As Canada’s largest ASIC repair center, we have handled thousands of Antminer repairs since 2016.