| Error code:110 | Meaning:Inlet fan detcction speed error | Corresponding solutions: Check whether the fan connction is normal, or replace the power supply, or replace the fan |
| Error code:111 | Meaning:Outlet fan detection speed error | Corresponding solutions: |
| Error code:120 | Meaning:Inlet fan speed error(Deviation 2000+) | Corresponding solutions: |
| Error code:121 | Meaning:Outlet fan speed error(Deviation 2000+) | Corresponding solutions: |
| Error code:130 | Meaning:Inlet fan speed error | Corresponding solutions: |
| Error code:131 | Meaning:Outlet fan spced error | Corresponding solutions: |
| Error code:140 | Meaning:Fan speed is too high | Corresponding solutions: Please check the environment temperature |
| Error code:200 | Meaning:Power detection error | Corresponding solutions: Detecting the power output cable, or updating the latest firmware, or replacing the power supply |
| Error code:201 | Meaning:Power does not match the configuration file | Corresponding solutions: Updating to the latest software |
| Error code:202 | Meaning:Power output voltage error | Corresponding solutions: Updating to the latest software or check the power supply |
| Error code:203 | Meaning:Power supply protection | Corresponding solutions: Please check the environment temperature |
| Error code:204 | Meaning:Power supply current protection | Corresponding solutions: |
| Error code:205 | Meaning:Power current error | Corresponding solutions: Inspection of power supply in power grid |
| Error code:206 | Meaning:Power input voltage is low | Corresponding solutions: Improve power supply conditions and input voltage |
| Error code:207 | Meaning:Power input current protecting | Corresponding solutions: |
| Error code:210 | Meaning:Power status error | Corresponding solutions: Check the power failure code |
| Error code:213 | Meaning:Power input voltage and current do not match the power | Corresponding solutions: Replace the PSU |
| Error code:216 | Meaning:Power remained unchanged for a long time | Corresponding solutions: |
| Error code:217 | Meaning:Power set enable error | Corresponding solutions: |
| Error code:218 | Meaning:Power input voltage is lower than 230V for high power mode | Corresponding solutions: Increase input voltage,replace power supply |
| Error code:233 | Meaning:Overtemperature Protection of Power Output | Corresponding solutions: Plcase check the environment temperature |
| Error code:234 | Meaning:Overtemperature Protection of Power Output | Corresponding solutions: |
| Error code:235 | Meaning:Overtemperature Protection of Power Output | Corresponding solutions: |
| Error code:236 | Meaning:Overcurrent Protection of Power Output | Corresponding solutions: Please check the environment temperature and the copper wire screw(Recommend to use the protable electric screwdriver) |
| Error code:237 | Meaning:Overcurrent Protection of Power Output | Corresponding solutions: |
| Error code:238 | Meaning:Overcurrent Protection of Power Output | Corresponding solutions: |
| Error code:239 | Meaning:Overvoltage Protection of Power Output | Corresponding solutions: Check grid power |
| Error code:240 | Meaning:Low Voltage Protection for Power Output | Corresponding solutions: |
| Error code:241 | Meaning:Power output current imbalance | Corresponding solutions: Replace the power |
| Error code:243 | Meaning:Over-tempcrature Protection for Power Input | Corresponding solutions: Please check the environment temperature |
| Error code:244 | Meaning:Over-temperature Protection for Power Input | Corresponding solutions: |
| Error code:245 | Meaning:Over-tempcrature Protection for Power Input | Corresponding solutions: |
| Error code:246 | Meaning:Overcurrent Protection for Power Input | Corresponding solutions: |
| Error code:247 | Meaning:Overcurrent Protection for Power Input | Corresponding solutions: |
| Error code:248 | Meaning:Overvoltage Protection for Power Input | Corresponding solutions: Check grid power |
| Error code:249 | Meaning:Overvoltage Protection for Power Input | Corresponding solutions: |
| Error code:250 | Meaning:Undervoltage Protection for Power Input | Corresponding solutions: |
| Error code:251 | Meaning:Undervoltage Protection for Power Input | Corresponding solutions: |
| Error code:253 | Meaning:Power Fan Error | Corresponding solutions: Replace the power supply |
| Error code:254 | Meaning:Power Fan Error | Corresponding solutions: |
| Error code:255 | Meaning:Protection of over power output | Corresponding solutions: Please check the environment temperature |
| Error code:256 | Meaning:Protection of over power output | Corresponding solutions: |
| Error code:257 | Meaning:Input over current protection of power supply primary side | Corresponding solutions: Try to power off and restart, no effect to replace the power supply |
| Error code:263 | Meaning:Power communication warning | Corresponding solutions: Check whether the screws of the control board are locked |
| Error code:264 | Meaning:Power communication error | Corresponding solutions: |
| Error code:267 | Meaning:Power watchdog protection | Corresponding solutions: Contact the technician in time |
| Error code:268 | Meaning:Power output over-current protection | Corresponding solutions: Check the ambient temperature, check the copper bar screw |
| Error code:269 | Meaning:Power input over-current protection | Corresponding solutions: Improve power supply conditions and input voltage |
| Error code:270 | Meaning:Power input over-voltage protection | Corresponding solutions: Inspection of input voltage in power grid |
| Error code:271 | Meaning:Power input under-voltage protection | Corresponding solutions: |
| Error code:272 | Meaning:Warning of excessive power output of power supply |
Corresponding solutions: Please check the environment temperature |
| Error code:273 | Meaning:Power input power too high warning | Corresponding solutions: |
| Error code:274 | Meaning:Power fan warning | Corresponding solutions: Check if the power fan is blocked and may need to be replaced |
| Error code:275 | Meaning:Power over temperature warning | Corresponding solutions: Please check the environment temperature |
| Error code:300 | Meaning:SM0 temperature sensor detection error | Corresponding solutions: Check the connection of the hash board |
| Error code:301 | Meaning:SM1 temperature sensor detection error | Corresponding solutions: |
| Error code:302 | Meaning:SM2 temperature sensor detection error | Corresponding solutions: |
| Error code:320 | Meaning:SM0 board temperature sensor communication error | Corresponding solutions: Check if the control panel screws are locked, check the adapter plate and the cable contacts |
| Error code:321 | Meaning:SM1 board temperature sensor communication error | Corresponding solutions: |
| Error code:322 | Meaning:SM2 board temperature sensor communication error | Corresponding solutions: |
| Error code:329 | Meaning:Control board temperature sensor communication error |
Corresponding solutions: Replace the power supply |
| Error code:350 | Meaning:SM0 tempcrature protection | Corresponding solutions: Check the environment temperature (Recommend to use the GS320 infrared thermometer) |
| Error code:351 | Meaning:M1 tempcrature protection | Corresponding solutions: |
| Error code:352 | Meaning:SM2 tempcrature protection | Corresponding solutions: |
| Error code:360 | Meaning:The temperature of the hash board is overheating | Corresponding solutions: |
| Error code:410 | Meaning:SMO detect eeprom error | Corresponding solutions: Check adapter plate and cable contact |
| Error code:411 | Meaning:SM1 detect eeprom error | Corresponding solutions: |
| Error code:412 | Meaning:SM2 detect eeprom error | Corresponding solutions: |
| Error code:420 | Meaning:SM0 parser eeprom error | Corresponding solutions: Upgrade firmware |
| Error code:421 | Meaning:SM1 parser eeprom error | Corresponding solutions: |
| Error code:422 | Meaning:SM2 parser eeprom error | Corresponding solutions: |
| Error code:430 | Meaning:SM0 chip bin type error | Corresponding solutions: |
| Error code:431 | Meaning:SM1 chip bin type error | Corresponding solutions: |
| Error code:432 | Meaning:SM2 chip bin type error | Corresponding solutions: |
| Error code:440 | Meaning:SM0 eeprom chip num X error | Corresponding solutions: |
| Error code:441 | Meaning:SM1 eeprom chip num X error | Corresponding solutions: |
| Error code:442 | Meaning:SM2 eeprom chip num X error | Corresponding solutions: |
| Error code:450 | Meaning:SM0 eeprom xfer error | Corresponding solutions: Check adapter board and wiring contacts.Upgrade firmware |
| Error code:451 | Meaning:SM1 eeprom xfer error | Corresponding solutions: |
| Error code:452 | Meaning:SM2 eeprom xfer error | Corresponding solutions: |
| Error code:510 | Meaning:SM0 miner type error | Corresponding solutions: The version and type of hashboard are inconsistent, replace the correct hashboard |
| Error code:511 | Meaning:SM1 miner type error | Corresponding solutions: |
| Error code:512 | Meaning:SM2 miner type error | Corresponding solutions: |
| Error code:520 | Meaning:SM0 bin type error | Corresponding solutions: If the chip type of the hash board is inconsistent, replace the correct hash board. |
| Error code:521 | Meaning:SM1 bin type error | Corresponding solutions: |
| Error code:522 | Meaning:SM2 bin type error | Corresponding solutions: |
| Error code:530 | Meaning:SM0 board is not detected | Corresponding solutions: Check the adapter board wiring and cablc, or replace the control board to check whether the hash board connector is soldered |
| Error code:531 | Meaning:SM1 board is not detected | Corresponding solutions: |
| Error code:532 | Meaning:SM2 board is not detected | Corresponding solutions: |
| Error code:540 | Meaning:The number of SM0 chips is incomplete | Corresponding solutions: Check adapter plate and cable contact |
| Error code:541 | Meaning:The number of SM1 chips is incomplete | Corresponding solutions: |
| Error code:542 | Meaning:The number of SM2 chips is incomplete | Corresponding solutions: |
| Error code:550 | Meaning:SM0 has bad chips | Corresponding solutions: Replace the bad chip in the print position |
| Error code:551 | Meaning:SM1 has bad chips | Corresponding solutions: |
| Error code:552 | Meaning:SM2 has bad chips | Corresponding solutions: |
| Error code:560 | Meaning:SM0 loss balance | Corresponding solutions: Plug in the adapter plate, and then screw in the power connection hash board again |
| Error code:561 | Meaning:SM1 loss balance | Corresponding solutions: |
| Error code:562 | Meaning:SM2 loss balance | Corresponding solutions: |
| Error code:590 | Meaning:SM0 frequency is too low | Corresponding solutions: Replace the hash board and place the hash boards which reported the same error together |
| Error code:591 | Meaning:SM1 frequency is too low | Corresponding solutions: |
| Error code:592 | Meaning:SM2 frequency is too low | Corresponding solutions: |
| Error code: | Meaning: | Corresponding solutions: |
| Error code:600 | Meaning:Environment temperature is too high | Corresponding solutions: Check the environment temperature |
| Error code:610 | Meaning:If the ambient temperature is too high in high performance mode, return to normal mode | Corresponding solutions: Check the ambient temperature, high performance mode needs to be ontrolled below 30 ℃ |
| Error code:701 | Meaning:Control board no support chip | Corresponding solutions: Upgrade the corresponding type of firmware |
| Error code:710 | Meaning:Control board error | Corresponding solutions: Update to the latest firmware |
| Error code:712 | Meaning:Control board rebooted as exception | Corresponding solutions: Updating the latest firmware.Check whether the control board screw is locked properly |
| Error code:800 | Meaning:cgminer checksum error | Corresponding solutions: Re-upgrade firmware |
| Error code:801 | Meaning:system-monitor checksum error | Corresponding solutions: |
| Error code:802 | Meaning:system-monitor checksum error | Corresponding solutions: |
| Error code:2000 | Meaning:No pool information configured | Corresponding solutions: Check pool configuration |
| Error code:2010 | Meaning:All mining pool connections failed | Corresponding solutions: Check the network or mining pools setting |
| Error code:2020 | Meaning:Mining pool0 connection failed | Corresponding solutions: |
| Error code:2021 | Meaning:Mining pool1 connection failed | Corresponding solutions: |
| Error code:2022 | Meaning:Mining pool2 connection failed | Corresponding solutions: |
| Error code:2030 | Meaning:Mining pool rejcction rate is too high | Corresponding solutions: Check the network or mining pool setting, and the mining setting of the cryptocurrency |
| Error code:2040 | Meaning:The pool does not support the asicboost mode |
Corresponding solutions: Check pool configuration |
| Error code:2310 | Meaning:Hash rate is too low | Corresponding solutions: Check input voltage, network environment, and ambient temperature |
| Error code:2320 | Meaning:Hash rate is too low | Corresponding solutions: |
| Error code:2340 | Meaning:The loss of hash rate is too high | Corresponding solutions: |
| Error code:2350 | Meaning:The loss of hash rate is too high | Corresponding solutions: |
| Error code:5070 | Meaning:SM0 water velocity is abnormal | Corresponding solutions: Check if the water flow is normal |
| Error code:5071 | Meaning:SM1 water velocity is abnormal | Corresponding solutions: |
| Error code:5072 | Meaning:SM2 water velocity is abnormal | Corresponding solutions: |
| Error code:5110 | Meaning:SM0 Frequency Up Timeout | Corresponding solutions: reboot |
| Error code:5111 | Meaning:SM1 Frequency Up Timeout | Corresponding solutions: |
| Error code:5112 | Meaning:SM2 Frequency Up Timeout | Corresponding solutions: |
| Error code:8410 | Meaning:Software version error (M2x miner with M3x firmware, or M3x with M2x firmware) | Corresponding solutions: Upgrade to the correct firmware version |
| Error code:100001 | Meaning:/antiv/signature Illegal | Corresponding solutions: Upgrade the latest firmware or burn the card |
| Error code:100002 | Meaning:/antiv/dig/initd.dig Illegal | Corresponding solutions: |
| Error code:100003 | Meaning:/antiv/dig/pf_partial.dig Illegal | Corresponding solutions: |
| Error code:PSU Error code | Meaning:Reason | Corresponding solutions: processing method |
| Error code:0x0001 | Meaning:Input undervoltage | Corresponding solutions: Check the power supply |
| Error code:0x0002 | Meaning:Temperature sampling over temperature protection of power radiator | Corresponding solutions: Power on again after 10 minutes of power failure. If it occurs again, replace the power supply |
| Error code:0x0004 | Meaning:Temperature sampling over temperature protection of power radiator |
Corresponding solutions: |
| Error code:0x0008 | Meaning:Over temperature protection of environmental emperature sampling in power supply | Corresponding solutions: |
| Error code:0x0010 | Meaning:Primary side over current | Corresponding solutions: Power on again after 10 minutes of power failure. If it occurs again, replace the power supply |
| Error code:0x0020 | Meaning:Output undervoltage | Corresponding solutions: Check the power supply |
| Error code:0x0040 | Meaning:Output over current (continuous load 320A for more than 2S) | Corresponding solutions: Tighten the copper bar screw again |
| Error code:0x0080 | Meaning:Primary side over current | Corresponding solutions: Power on again after 10 minutes of power failure. If it occurs again, replace the power supply |
| Error code:0x0100 | Meaning:Single circuit overcurrent (protection point 120a) | Corresponding solutions: Check the PSU |
| Error code:0x0200 | Meaning:Single circuit overcurrent (protection point 120a) | Corresponding solutions: |
| Error code:0x0400 | Meaning:Single circuit overcurrent (protection point 120a) |
Corresponding solutions: |
| Error code:0x0800 | Meaning:Fan failure | Corresponding solutions: Replace the PSU |
| Error code:0x1000 | Meaning:Output over current (continuous load of 310A for more than 5min) |
Corresponding solutions: Check the PSU |
| Error code:0x2000 | Meaning:Output over current (continuous load 295A for more than 10min) |
Corresponding solutions: |
| Meaning: | Corresponding solutions: | |
Whatsminer Fault Code Troubleshooting Guide
Start with safety and logs
Power down before opening a miner, label cables before moving boards, and capture logs before repeated reboots erase useful evidence. Record model, firmware, pool, uptime, fan speed, temperature, reject rate, chain count, and the exact error text.
Confirm the fault class
Separate configuration faults from hardware faults first. Pool errors, DNS failures, bad worker names, overheating, weak power, fan faults, and missing hashboards can look similar from the dashboard but require different fixes.
Document the test path
Change one variable at a time and keep the before/after result. Note cable swaps, PSU swaps, firmware changes, pool changes, fan replacements, ambient temperature, and whether the fault follows a hashboard, control board, network, or power source.
When to escalate
Escalate to professional repair when there is a burned smell, melted connector, breaker trip, corrosion, repeated hashboard loss, liquid exposure, or a board-level fault that returns after a basic cable, power, firmware, and airflow check.
After the fix
Run the miner long enough to confirm stable accepted hashrate, fan behavior, chip temperature, reject rate, and pool-side reporting. A dashboard that looks normal for five minutes is not enough evidence for a recurring power, heat, or hashboard fault.
Last updated:
Editorial review and limitations
Reviewed by D-Central's mining hardware and ASIC repair editorial team for practical accuracy, buyer risk, repair context, and operational assumptions. Verify current hardware price, stock, network difficulty, BTC price, power rate, shipping, tax, firmware, and device condition before buying, hosting, repairing, or retiring mining hardware.
Last reviewed September 15, 2024. D-Central, Laval, Quebec.
Related products, repair, and setup paths
- how D-Central diagnoses ASIC repairs
- ASIC troubleshooting library
- ASIC manuals and repair guides
- replacement hashboards
- ASIC control boards
- ASIC power supplies
- S19 family replacement hashboard
- C52 replacement control board
- APW12 S19 power supply
- immersion cooling hub
- home immersion cooling guide
- ASIC miners for immersion planning
- ASIC cooling parts
- airflow shroud before immersion
- compare miner specs in the database
- ASIC repair support
- compare ASIC miner specs
- ASIC miner database
- Whatsminer M30S specs
- Whatsminer repair guide
- MicroBT Whatsminer M30S++
- Whatsminer M3x exhaust shroud
Last reviewed September 15, 2024.