On this page
Bitmain Antminer HS3 Blake2B+SHA3 official reference
Official Antminer HS3 reference: 9 TH/s, 2,079 W and 231 J/TH for Blake2B+SHA3/HNS, with exact integrated-PSU dual-input safety and support boundaries.
Quick answer
The Bitmain Antminer HS3 Blake2B+SHA3 official reference is a Blake2b+sha3 miner rated about 9 TH/s at roughly 2,079 W.
Full Specifications
| Model | Bitmain Antminer HS3 Blake2B+SHA3 official reference |
|---|---|
| Model Number | Antminer HS3 |
| Manufacturer | Bitmain |
| Algorithm | Blake2b+sha3 |
| Coins Mined | Unknown |
| Hashrate | 9 TH/s |
| Power Consumption | 2,079 W |
| Efficiency | 231 J/TH |
| Cooling | Air |
| Voltage Range | 200-240 V AC; 47-63 Hz; two 10 A inputs; 20 A maximum; both connected simultaneously |
| Operating Temperature | 0 C to 40 C |
| Dimensions | 430 x 195.5 x 290 mm |
| Weight | 16.1 kg net |
| Interface | RJ45 Ethernet 10/100M |
| Status | OEM support reference |
Evidence-controlled HS3 reference: Antminer HS3 is documented by Bitmain for the Blake2B+SHA3 algorithm and HNS source coin lane. Its TH/s and J/TH values are specific to this algorithm and must not be compared numerically across algorithms.
| Hashrate | Wall power at 25°C | Wall efficiency at 25°C |
|---|---|---|
| 9 TH/s ±3% | 2,079 W ±10% | 231 J/TH ±10% |
Electrical installation and shutdown
The APW12 power supply is integrated as part of the HS3 server. It requires 200–240 V AC, 47–63 Hz, and 20 A. The manual states that the equipment has two power inputs: both power supply sockets must be connected simultaneously for normal operation. To power the server off, switch off all power inputs. The equipment must connect to an earthed mains socket-outlet installed nearby and readily accessible.
Wrong input voltage can damage the miner. Have a qualified person verify the exact HS3/APW12 labels, both input paths, cords and connectors, circuit capacity, protection, conductors, disconnecting means, grounding, ventilation, and applicable requirements before energizing. Cord and connector models are not asserted.
Cooling, physical, and environmental facts
| Fans | Four 12038 fans; 5,200 RPM front and rear; 12 V / 2.35 A; 360 CFM mid airflow |
|---|---|
| Network | RJ45 Ethernet 10/100M |
| Miner dimensions | 430 × 195.5 × 290 mm, including PSU |
| Packaged dimensions | 570 × 316 × 430 mm |
| Net / gross weight | 16.1 kg including PSU / 17.7 kg |
| Operating / storage temperature | 0–40°C / -20–70°C |
| Operating humidity | 10–90% RH, non-condensing |
| Operating altitude | Up to 2,000 m |
The 20 A input maximum is specified at 40°C and 0 m altitude. From 900 m to 2,000 m, reduce the highest permitted operating temperature by 1°C for every 300 m increase.
Firmware, diagnostics, and repair
- Select HS3 and the exact installed revision in Bitmain’s firmware selector.
- Use Bitmain’s exact HS3 support hub for the manual, firmware, setup, reset, troubleshooting, and service resources.
- Read the exact HS3 Server Installation Guide before installation or shutdown.
- Use Bitmain’s generic miner diagnostic guide.
- Organize symptoms and logs with the ASIC fault finder.
- Request ASIC repair diagnosis with exact labels, photographs, logs, symptoms, and prior firmware actions.
Evidence boundaries: sound level, chip/count, hashboard count, controller model, cord/connector model, internal architecture, tuning, economics, residential suitability, heat-use, parts interchangeability, and cross-model compatibility are not asserted.
Primary sources: Bitmain’s HS3 specification, exact installation guide and support hub linked above, and official fan table. Bitmain’s current repair-cost table includes HS3. Reviewed August 28, 2026.