Elphapex DG Hydro 1 official manual and infrastructure reference
Official manual profile: 20 GH/s +/-3%, 6200 W +/-10% on-wall at 25 C, and 0.31 J/MH +/-10%, with exact three-phase and coolant boundaries.
Quick answer
The Elphapex DG Hydro 1 official manual and infrastructure reference is a Scrypt miner rated about 20 GH/s at roughly 6,200 W.
Full Specifications
| Model | Elphapex DG Hydro 1 official manual and infrastructure reference |
|---|---|
| Model Number | DG Hydro 1 |
| Manufacturer | Elphapex |
| Algorithm | Scrypt |
| Hashrate | 20 GH/s |
| Power Consumption | 6,200 W |
| Efficiency | 310 J/GH |
| Cooling | Hydro |
| Dimensions | 656 x 447 x 86 mm |
| Weight | 25 |
| Status | Lifecycle not independently verified |
DG Hydro 1 authenticated normal-mode profile
ElphaPex manual version 1.0.0 specifies 20,000 MH/s +/-3%, 6200 W on-wall at 25 C +/-10%, and 0.31 J/MH on-wall at 25 C +/-10%. The native manufacturer efficiency unit is J/MH and must not be relabeled J/TH or J/GH.
Electrical architecture
The integrated PSU requires 380-480 V AC, three phase plus protective ground, with 10 kW input architecture. Wrong voltage or incorrect three-phase wiring can damage the equipment. Facility supply, disconnect, breaker, conductors, connector and protection require qualified design from the equipment markings, manual and applicable code.
Hydraulic and environmental contract
The manual specifies approximately 1 L coolant per machine, at least 10 L/min flow, no more than 3.5 bar operating pressure, pH 8.5-9.5, and manufacturer-qualified deionized/custom water chemistry. Normal-mode inlet water is 20-50 C; overclocking-mode inlet water is 20-40 C. Humidity is 10-90% noncondensing, storage temperature -40 to 70 C, and altitude no higher than 2000 m. Coolant chemistry and replacement require the manufacturer’s testing guidance.
Physical and firmware scope
Unpackaged dimensions are 656 x 447 x 86 mm and packaged dimensions 760 x 590 x 245 mm. Net mass is 25 kg and gross mass 26.5 kg. The manual describes exact-model firmware update and recovery behavior but does not authorize arbitrary images; use only an authenticated DG Hydro 1 artifact with checksum and rollback plan.
The former acoustic, release, price, residential, heat-reuse and profitability claims are withheld because the manual does not support them.