On this page
Goldshell SC5 Pro two-mode specifications
Goldshell SC5 Pro exact two-mode Blake2b and SC matrix, label-scoped electrical boundaries, temperature conflict, and safe service routes.
Full Specifications
| Model | Goldshell SC5 Pro two-mode specifications |
|---|---|
| Model Number | SC5 Pro |
| Manufacturer | Goldshell |
| Algorithm | Blake2b |
| Coins Mined | Unknown |
| Noise Level | 55 dB |
| Voltage Range | 180-280 VAC |
| Status | Manufacturer-sourced two-mode specification |
Manufacturer-sourced two-mode specification
Goldshell SC5 Pro
Goldshell publishes Default and Low Power rows for one SC5 Pro model using Blake2b for SC. The rows remain paired exactly as published.
OEM operating modes
| Mode | Hashrate | Power | Efficiency |
|---|---|---|---|
| Default | 11 TH/s ±5% | 2820 W ±5% | 256 J/TH |
| Low Power | 8.8 TH/s ±5% | 2020 W ±5% | 229 J/TH |
Hashrate and power retain their separate OEM tolerances. No cross-row endpoint pairing or arithmetic replacement of the published efficiency is implied.
Electrical and environment boundary
- Input voltage
- 180–280 VAC
- OEM Power Cable label
- 16A
- Network
- Ethernet only
- Relative humidity
- ≤65%
- Fan specification
- 6000 rpm
The 16A value is reproduced only as Goldshell’s “Power Cable” field. It is not miner input current, facility current, breaker sizing, or continuous load. Frequency, phase, connector, overcurrent protection, conductor sizing, plug type, and internal or external PSU architecture remain unresolved. Confirm these from the exact nameplate and current manufacturer documentation.
Temperature-source conflict
The OEM table lists 0–35°C. The same page’s usage precautions specify 10–35°C. This reference uses conservative 10–35°C operating guidance; the lower table endpoint is disclosed but not recommended.
Shared physical and acoustic facts
- Miner dimensions
- 264 × 200 × 290 mm
- Miner weight
- 11.5 kg
- Package dimensions
- 370 × 305 × 450 mm
- Package weight
- 13.2 kg
- Noise
- ≤55 dB
Firmware boundary
No exact SC5 Pro artifact is identified in the official firmware roster reviewed. Do not choose firmware by family resemblance. Confirm an exact-model selector result through Goldshell support before updating, and never remove power during an active update.
Diagnosis and service
SC5 Pro II and every adjacent product remain separate identities. Their specifications, firmware, modes, and parts are not imported. Record the exact label, active mode, firmware, nameplate, symptoms, and logs before changes.
Fields intentionally unresolved
No release-price, profitability, residential-use, heat-reuse, tuning, silicon, controller, board, parts-interchangeability, frequency, phase, connector, protection, conductor, plug, or PSU-architecture claim is made.