JASMINER X16-P official specifications and electrical boundary
Exact OEM matrix, memory, conservative facility input, source conflicts, and current-compatibility limits.
Quick answer
The JASMINER X16-P official specifications and electrical boundary is a EtHash miner rated about 5800 MH/s at roughly 1,900 W.
Full Specifications
| Model | JASMINER X16-P official specifications and electrical boundary |
|---|---|
| Model Number | X16-P |
| Manufacturer | Jasminer |
| Algorithm | EtHash |
| Hashrate | 5800 MH/s |
| Power Consumption | 1,900 W |
| Efficiency | 0.32 J/MH |
| Weight | 14 kg |
| Status | Lifecycle not independently verified |
JASMINER X16-P official specifications and electrical boundary
The exact X16-P Power Server is rated at 5,800 MH/s ±10%, 1,900 W ±10%, and OEM-rated 0.32 J/MH ±10%. Direct arithmetic gives approximately 0.328 J/MH; the calculated value and manufacturer rating are kept distinct.
Memory, network, and environment
The OEM manual lists 8 GB memory, ETCHASH and ETHASH, RJ45 10/100/1000 Ethernet using shielded cable, Linux, fan cooling, a built-in PSU, 14 kg net weight, 0–40°C, 5–95% RH non-condensing, and altitude no greater than 2,000 m.
Electrical boundary
The formal specification table lists 200–240 VAC, 50/60 Hz, 12.5 A. Separate setup prose says 120–240 V, creating a manufacturer conflict. This reference uses the conservative formal 200–240 V range and does not approve 120 V operation. Exact cord, plug, connector, conductor count, branch protection, power factor, and continuous-load installation details were not published; a qualified person must verify the delivered nameplate and site requirements.
Physical and acoustic conflicts
The manual lists 374 × 143 × 293 mm in H × W × L order, while a manufacturer-controlled product page lists 212 × 300 × 374 mm. No single canonical dimension is asserted. The regional page lists an acoustic ceiling of ≤70 dB; the manual does not provide a numeric result. The ceiling is manufacturer-published, not an independent test.
Compatibility boundary
The manual documents ETC and ETC+ZIL configuration and performance modes. That establishes publication-time capability, not evergreen DAG fit, current pool support, profitability, or exact firmware safety. No model-specific firmware filename, version, or checksum was found. Verify the exact board and current network before operation or updating.
MSRP, BTU, home suitability, solo mining, generic heating, repair, tuning, and current economics are intentionally withheld.