On this page
JASMINER X16-Q evidence and service reference
JASMINER X16-Q evidence-controlled manual reference: identity, algorithms, memory, network, physical and equipment-rating boundaries; performance withheld.
Full Specifications
| Model | JASMINER X16-Q evidence and service reference |
|---|---|
| Model Number | X16-Q |
| Manufacturer | Jasminer |
| Algorithm | EtHash |
| Coins Mined | Ethereum Classic (ETC) |
| Hashrate | TH/s |
| Power Consumption | W |
| Efficiency | — |
| Cooling | Air |
| Interface | Ethernet |
| Status | Evidence-controlled manual reference / performance withheld |
Evidence-controlled JASMINER X16-Q reference: this page uses the manufacturer-authored X16-Q user manual submitted with the device’s regulatory record. Performance claims are withheld where durable exact-product evidence conflicts or is unavailable.
Manual-supported identity and functions
| Product | JASMINER X16-Q high-throughput quiet server |
|---|---|
| Developer named by manual | Sunlune Technology Development (Beijing) Co., Ltd. |
| Algorithms named by manual | ETCHASH and ETHASH |
| Memory | 8 GB |
| Operating system | Linux |
| Network | RJ45 Ethernet 10/100/1000M and 802.11b/g/n 2.4 GHz Wi-Fi |
| Ports | TF card, power, and RJ45 network ports |
Algorithm identity does not establish present network, coin, pool, memory-capacity, or DAG compatibility. Verify current workload requirements separately.
Physical and cooling fields
| Manual dimensions | 443 mm high × 410 mm long × 132.5 mm wide |
|---|---|
| Weight | 10 kg |
| Cooling style | Fans |
| Power supply | Built in |
The manual does not establish a publishable fan count, fan speed, acoustic measurement, storage environment, component roster, controller model, or parts interchangeability.
Manual equipment electrical rating
| Input-voltage rating | 120–240 V |
|---|---|
| Frequency | 50/60 Hz |
| Current rating | 10 A |
| Power printed in manual equipment table | 1,200 W ±10% |
Scope: 1,200 W ±10% is the value printed in the manufacturer-authored manual’s equipment table. It is presented only as that manual equipment rating. It is not asserted as typical operating power, wall power at a named mode, or a value paired to any hashrate. Do not derive efficiency from it.
The built-in PSU boundary means an external-PSU sizing calculation is inappropriate. Before energizing the unit, a qualified person must verify the nameplate, exact hardware revision, cord and inlet, supply, branch protection, conductors, grounding, disconnect, and local requirements. The manual prohibits confined placement, disassembly, and touching the hot case during operation.
Performance conflict: withheld
Previously displayed hashrate, operating power, efficiency, and noise values are not published here. Available secondary product material presents a performance lane that cannot be safely reconciled with the manual’s equipment power table using durable official product evidence. No value from one lane is combined with a value from the other, and no performance product schema is emitted.
Setup and service boundaries
- Regulatory manual record and document index
- Manufacturer-authored X16-Q manual copy
- Use the manual procedures for placement, network discovery, login, pool configuration, Wi-Fi, reset, restart, shutdown, and firmware update only after confirming the exact X16-Q revision.
- No firmware download is linked because an exact, verified official manufacturer artifact was not established. Do not use a reseller file or similarly named model image.
- No hashboard, controller, PSU, fan, cable, memory, or other part is represented as compatible without exact revision evidence.
- Organize symptoms and logs; request local repair triage
Withheld claims: no economics, residential-use, heat-use, solo-mining, tuning, overclocking, firmware-compatibility, parts-interchangeability, release-date, price, or acoustic claim is asserted. Reviewed August 28, 2026.
Broken miner? Get a real quote.
Tell us the symptom and get an instant repair-tier estimate ($95 / $145 / $195 CAD). Mail-in from across Canada, bench in Montreal, Quebec.
Send it to D-Central — start a repair →