Bitdeer SEALMINER A2 Hydro official specifications and infrastructure boundary
SEALMINER A2 Hydro: official nominal/bin performance, exact ranges and tolerances, with cooling, electrical, acoustic and firmware limits.
Quick answer
The Bitdeer SEALMINER A2 Hydro official specifications and infrastructure boundary is a SHA-256 ASIC whose manufacturer listed Bitcoin-family workload associations rated about 446 TH/s at roughly 7,359 W.
Full Specifications
| Model | Bitdeer SEALMINER A2 Hydro official specifications and infrastructure boundary |
|---|---|
| Model Number | SEALMINER A2 Hydro |
| Manufacturer | Bitdeer |
| Algorithm | SHA-256 |
| Hashrate | 446 TH/s |
| Power Consumption | 7,359 W |
| Calculated nominal efficiency | 16.5 J/TH |
| Cooling | Hydro |
| Dimensions | 482 x 665 x 88 mm |
| Weight | 20.5 kg |
SEALMINER A2 Hydro official performance contract
- Comparison nominal/bin: 446 TH/s at 7359 W
- Manufacturer efficiency: 16.5 J/TH
- Published hashrate range: 446–446 TH/s
- Published power range: 7359–7359 W
Exact launch nominal; Normal and High Hash coolant modes have different inlet-temperature limits.
SHA-256 and the manufacturer-listed BTC, BCH and BSV workload labels are retained. They are not profitability or current network guarantees.
Hydro-cooling and facility boundary
The A2 Hydro guide specifies Normal mode coolant inlet 20–55 °C and High Hash inlet 20–45 °C, flow at least 10.2 L/min and inlet pressure no more than 350 kPa. Use distilled water with corrosion inhibitor and antifreeze as conditions require; copper piping is prohibited. Cooling must circulate, purge and pass leak/condensation checks before energizing. Drain promptly when disconnected, stored or exposed to freezing risk.
Hydro units ship without power cables by default. Replacement-PSU dimensions and mass are not whole-miner dimensions.
Acoustic, physical and firmware boundary
Manufacturer language such as low-noise or near-silent is qualitative. No absolute dBA test protocol is published, so the former 50/75 dB values are withheld. Whole-miner dimensions, weights and environment fields are withheld where accessible first-party text did not authenticate them.
Firmware is exact-model and revision gated. Do not cross-flash Air/Hydro, base/Pro or A2/A3 artifacts. A2 Air Single Input and Double Input packages are distinct. A future CTA requires exact selector, controller/board match, version, checksum and rollback instructions.
Current revenue, profit, MSRP, BTU and home-suitability claims are unavailable.
Exact physical, electrical and environmental table
- Miner dimensions: 482 x 665 x 88 mm; net weight: 20.5 kg
- Package: 567 x 787 x 203 mm; gross weight: 23 kg
- Input contract: {"voltage":"380-480 VAC","phase":"3-phase","max_psu_input_w":10000,"max_current_a":20,"frequency":"47-63 Hz","connector":null}
- Environment/cooling contract: {"coolant_inlet_c":"20-55","storage_c":"-30 to 70 after draining","rh":"10-90% noncondensing","liquid_pressure_bar_max":3.5,"pure_water_flow_l_min":10.199999999999999289457264239899814128875732421875,"glycol_30pct_flow_l_min":11}
Maximum PSU input and current are equipment-table limits, not branch-circuit designs. Connector, phase or protective-device fields remain unresolved wherever the manufacturer table is silent.