Quick answer
Not every Bitcoin ASIC can be cooled every way. This matrix maps 15 model families to how each can actually be cooled: its stock cooling, whether Bitmain/MicroBT ship a FACTORY hydro (water) variant, whether a FACTORY immersion variant ships, and whether the air unit can be converted to aftermarket immersion. Air units are cheapest and loudest; a factory hydro or immersion SKU is a purpose-built rack-dense unit; and any air ASIC can be converted to immersion — but that voids the manufacturer warranty.
Choose air for home/low-cost, a FACTORY hydro/immersion SKU for the densest, quietest, highest-overclock deployments, and aftermarket immersion only if you accept the warranty trade-off. Factory-variant cells here name a real SKU from the D-Central catalog; where none exists the cell is "—".
Download CSV Download JSON REST API →
Comparing the cooling methods themselves? See the ASIC cooling-methods comparison. Planning to reuse the heat? Use the mining heat calculator and the heat-reuse matrix. Every model here links to its full profile in the miner database.
| Model family | Stock | Factory hydro | Factory immersion | Aftermarket immersion |
|---|---|---|---|---|
| Antminer S9 / S9j / S9k | Forced air (2 fans) | Yes S9 Hydro (18 TH/s) | — | Convertible (voids warranty) |
| Antminer S17 / T17 | Forced air (4 fans) | — | — | Convertible (voids warranty) |
| Antminer T19 | Forced air (4 fans) | Yes T19 Hydro, T19 Pro Hyd | — | Convertible (voids warranty) |
| Antminer S19 | Forced air (4 fans) | Yes S19 Hydro | — | Convertible (voids warranty) |
| Antminer S19 Pro / S19 Pro+ | Forced air (4 fans) | Yes S19 Pro Hyd (177 TH/s), S19 Pro+ Hyd (191–198 TH/s) | — | Convertible (voids warranty) |
| Antminer S19j Pro / S19k Pro | Forced air (4 fans) | — | — | Convertible (voids warranty) |
| Antminer S19 XP / S19 XP+ | Forced air (4 fans) | Yes S19 XP Hyd (257 TH/s), S19 XP+ Hyd (279–293 TH/s), S19e XP Hydro (251 TH/s) | — | Convertible (voids warranty) |
| Antminer S21 | Forced air (4 fans) | Yes S21 Hyd (335 TH/s) | Yes S21 Immersion (227 / 301 TH/s) | Convertible (voids warranty) |
| Antminer S21 Pro | Forced air (4 fans) | — | — | Convertible (voids warranty) |
| Antminer S21+ / S21e | Forced air (4 fans) | Yes S21+ Hyd (358 TH/s), S21e Hyd (288–332 TH/s), S21e XP Hyd (3U) | — | Convertible (voids warranty) |
| Antminer S21 XP | Forced air (4 fans) | Yes S21 XP Hyd, S21 XP+ Hyd (500 TH/s) | Yes S21 XP Immersion | Convertible (voids warranty) |
| Antminer S23 | Forced air (4 fans) | Yes S23 Hyd, S23 Hyd (3U) | Yes S23 Immersion (368 / 442 TH/s) | Convertible (voids warranty) |
| Whatsminer M30S / M30S+ / M30S++ | Forced air (2 fans) | Yes M30S++ (Hydro) | — | Convertible (voids warranty) |
| Whatsminer M50 / M60 series | Forced air (2 fans) | Yes M53 / M53S / M53S+ (M50-gen hydro), M63 / M63S / M63S+ (M60-gen hydro) | Yes M56 / M56S / M56S+ (M50-gen immersion), M66 / M66S (M60-gen immersion) | Convertible (voids warranty) |
| Antminer L7 / L9 (Scrypt) | Forced air (4 fans) | — | — | Convertible (voids warranty) |
Antminer S9 / S9j / S9k S9
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (2 fans) |
| Factory hydro variant | Yes S9 Hydro (18 TH/s) |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; the S9 Hydro loop feeds a low-grade hot-water/radiant loop. |
Notes: The legacy 16nm workhorse. A factory S9 Hydro shipped; the standard S9/S9j/S9k are forced-air and are the most commonly immersion-converted model at home scale.
Antminer S17 / T17 S17
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | — |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat. |
Notes: No factory liquid variant. The 7nm S17/T17 generation ran hot and is a frequent aftermarket-immersion candidate to stabilise hashboard temperatures.
Antminer T19 S19
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes T19 Hydro, T19 Pro Hyd |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; T19 Hydro coolant ~45–55°C → hot water. |
Notes: Value tier of the S19 platform; a factory T19 Hydro exists alongside the air model.
Antminer S19 S19
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S19 Hydro |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; S19 Hydro coolant ~45–55°C → hot water/radiant. |
Notes: Base S19 (BM1398). A factory S19 Hydro shipped for rack-dense deployments.
Antminer S19 Pro / S19 Pro+ S19
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S19 Pro Hyd (177 TH/s), S19 Pro+ Hyd (191–198 TH/s) |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; hydro loop ~45–55°C → hot water/radiant. |
Notes: The Pro and Pro+ both ship factory hydro variants at higher hashrate than the air units.
Antminer S19j Pro / S19k Pro S19
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | — |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat. |
Notes: No factory liquid variant for the j Pro / k Pro. Within the S19 line the factory hydro flagships are the S19 Pro Hyd and S19 XP Hyd.
Antminer S19 XP / S19 XP+ S19
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S19 XP Hyd (257 TH/s), S19 XP+ Hyd (279–293 TH/s), S19e XP Hydro (251 TH/s) |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; hydro loop ~45–55°C → hot water/radiant. |
Notes: The 5nm XP (BM1366) tops the S19 line; its factory hydro variants push well past the air hashrate.
Antminer S21 S21
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S21 Hyd (335 TH/s) |
| Factory immersion variant | Yes S21 Immersion (227 / 301 TH/s) |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; hydro/immersion capture a larger share for hot water or radiant loops. |
Notes: First S21-generation model with all three factory form factors in the catalog: air, hydro, and a factory Immersion SKU.
Antminer S21 Pro S21
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | — |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat. |
Notes: The S21 Pro (BM1370) ships as an air unit; within the S21 series the factory liquid units are the S21 Hyd/Immersion, S21+ Hyd, S21e Hyd and S21 XP Hyd/Immersion rather than a dedicated "Pro Hyd".
Antminer S21+ / S21e S21
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S21+ Hyd (358 TH/s), S21e Hyd (288–332 TH/s), S21e XP Hyd (3U) |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; hydro loop ~45–55°C → hot water/radiant. |
Notes: The + and e sub-lines ship factory hydro units, several in a rack-dense 3U form factor.
Antminer S21 XP S21
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S21 XP Hyd, S21 XP+ Hyd (500 TH/s) |
| Factory immersion variant | Yes S21 XP Immersion |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; hydro/immersion capture a larger share for hot water or radiant loops. |
Notes: Top of the S21 line; factory air, hydro (incl. a 500 TH/s XP+ Hyd) and a factory Immersion SKU all exist.
Antminer S23 S23
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | Yes S23 Hyd, S23 Hyd (3U) |
| Factory immersion variant | Yes S23 Immersion (368 / 442 TH/s) |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; hydro/immersion capture a larger share for hot water or radiant loops. |
Notes: Next-generation flagship; ships in air, hydro (incl. 3U) and a factory Immersion SKU.
Whatsminer M30S / M30S+ / M30S++ M30
| Manufacturer | MicroBT |
|---|---|
| Stock cooling | Forced air (2 fans) |
| Factory hydro variant | Yes M30S++ (Hydro) |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; the M30S++ Hydro loop feeds a hot-water/radiant loop. |
Notes: MicroBT ships a factory M30S++ Hydro. (MicroBT also offers hydro/immersion variants in its later M5x/M6x lines; the M30S++ Hydro is the one currently profiled in the D-Central catalog.)
Whatsminer M50 / M60 series M50/M60
| Manufacturer | MicroBT |
|---|---|
| Stock cooling | Forced air (2 fans) |
| Factory hydro variant | Yes M53 / M53S / M53S+ (M50-gen hydro), M63 / M63S / M63S+ (M60-gen hydro) |
| Factory immersion variant | Yes M56 / M56S / M56S+ (M50-gen immersion), M66 / M66S (M60-gen immersion) |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat; the M5x/M6x hydro loops feed a hot-water/radiant loop. |
Notes: MicroBT encodes cooling in the model number's middle digit: M50/M60 are air, M53/M63 are hydro (water), and M56/M66 are immersion — so each generation ships all three form factors, and all are profiled in the D-Central catalog.
Antminer L7 / L9 (Scrypt) L (Scrypt)
| Manufacturer | Bitmain |
|---|---|
| Stock cooling | Forced air (4 fans) |
| Factory hydro variant | — |
| Factory immersion variant | — |
| Aftermarket immersion | Convertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger. |
| Heat-reuse fit | Air exhaust ~55–70°C → space heat. |
Notes: Litecoin/Dogecoin Scrypt miners. The air L7/L9 have no factory liquid variant; the separate, newer L11 line adds a Scrypt hydro tier (the L11 Hyd 2U).
Factory hydro/immersion cells name a variant only where that exact SKU exists in the live D-Central miner database; cooling-method characteristics are grounded in the D-Central Mining Bible and mirror the cooling-methods comparison. Aftermarket immersion or hydro conversion of an air unit voids the manufacturer warranty — confirm terms with the manufacturer before purchase or conversion. Free CSV/JSON under CC BY 4.0.
Related products, repair, and setup paths
- how D-Central diagnoses ASIC repairs
- ASIC troubleshooting library
- ASIC manuals and repair guides
- replacement hashboards
- ASIC control boards
- ASIC power supplies
- immersion cooling hub
- home immersion cooling guide
- ASIC miners for immersion planning
- ASIC cooling parts
- airflow shroud before immersion
- compare miner specs in the database
- ASIC repair support
- compare ASIC miner specs
- ASIC miner database
- Antminer S19 specs and profitability
- buy a tested Antminer S19
- Antminer S19 maintenance guide
- Antminer S19 repair service
- Antminer S21 specs
- Bitmain Antminer S21
- Antminer S21 maintenance guide
- BM1370BC S21 Pro chip
- Antminer S9 specs
- Bitmain Antminer S9
- Antminer S9 maintenance guide
- S9 hashboard repair parts bundle
- Whatsminer M30S specs
- Whatsminer repair guide
- MicroBT Whatsminer M30S++
- Whatsminer M3x exhaust shroud
Last reviewed July 12, 2026.