Skip to content

Bitcoin accepted at checkout  |  Ships from Laval, QC, Canada  |  Expert support since 2016

ASIC Cooling-Fitment Matrix: Air vs Hydro vs Immersion by Model

Quick answer

Not every Bitcoin ASIC can be cooled every way. This matrix maps 15 model families to how each can actually be cooled: its stock cooling, whether Bitmain/MicroBT ship a FACTORY hydro (water) variant, whether a FACTORY immersion variant ships, and whether the air unit can be converted to aftermarket immersion. Air units are cheapest and loudest; a factory hydro or immersion SKU is a purpose-built rack-dense unit; and any air ASIC can be converted to immersion — but that voids the manufacturer warranty.

Choose air for home/low-cost, a FACTORY hydro/immersion SKU for the densest, quietest, highest-overclock deployments, and aftermarket immersion only if you accept the warranty trade-off. Factory-variant cells here name a real SKU from the D-Central catalog; where none exists the cell is "—".

Download CSV Download JSON REST API →

Comparing the cooling methods themselves? See the ASIC cooling-methods comparison. Planning to reuse the heat? Use the mining heat calculator and the heat-reuse matrix. Every model here links to its full profile in the miner database.

Model familyStockFactory hydroFactory immersionAftermarket immersion
Antminer S9 / S9j / S9kForced air (2 fans)Yes S9 Hydro (18 TH/s)Convertible (voids warranty)
Antminer S17 / T17Forced air (4 fans)Convertible (voids warranty)
Antminer T19Forced air (4 fans)Yes T19 Hydro, T19 Pro HydConvertible (voids warranty)
Antminer S19Forced air (4 fans)Yes S19 HydroConvertible (voids warranty)
Antminer S19 Pro / S19 Pro+Forced air (4 fans)Yes S19 Pro Hyd (177 TH/s), S19 Pro+ Hyd (191–198 TH/s)Convertible (voids warranty)
Antminer S19j Pro / S19k ProForced air (4 fans)Convertible (voids warranty)
Antminer S19 XP / S19 XP+Forced air (4 fans)Yes S19 XP Hyd (257 TH/s), S19 XP+ Hyd (279–293 TH/s), S19e XP Hydro (251 TH/s)Convertible (voids warranty)
Antminer S21Forced air (4 fans)Yes S21 Hyd (335 TH/s)Yes S21 Immersion (227 / 301 TH/s)Convertible (voids warranty)
Antminer S21 ProForced air (4 fans)Convertible (voids warranty)
Antminer S21+ / S21eForced air (4 fans)Yes S21+ Hyd (358 TH/s), S21e Hyd (288–332 TH/s), S21e XP Hyd (3U)Convertible (voids warranty)
Antminer S21 XPForced air (4 fans)Yes S21 XP Hyd, S21 XP+ Hyd (500 TH/s)Yes S21 XP ImmersionConvertible (voids warranty)
Antminer S23Forced air (4 fans)Yes S23 Hyd, S23 Hyd (3U)Yes S23 Immersion (368 / 442 TH/s)Convertible (voids warranty)
Whatsminer M30S / M30S+ / M30S++Forced air (2 fans)Yes M30S++ (Hydro)Convertible (voids warranty)
Whatsminer M50 / M60 seriesForced air (2 fans)Yes M53 / M53S / M53S+ (M50-gen hydro), M63 / M63S / M63S+ (M60-gen hydro)Yes M56 / M56S / M56S+ (M50-gen immersion), M66 / M66S (M60-gen immersion)Convertible (voids warranty)
Antminer L7 / L9 (Scrypt)Forced air (4 fans)Convertible (voids warranty)

Antminer S9 / S9j / S9k S9

ManufacturerBitmain
Stock coolingForced air (2 fans)
Factory hydro variantYes S9 Hydro (18 TH/s)
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; the S9 Hydro loop feeds a low-grade hot-water/radiant loop.

Notes: The legacy 16nm workhorse. A factory S9 Hydro shipped; the standard S9/S9j/S9k are forced-air and are the most commonly immersion-converted model at home scale.

Confidence: high

Antminer S17 / T17 S17

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variant
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat.

Notes: No factory liquid variant. The 7nm S17/T17 generation ran hot and is a frequent aftermarket-immersion candidate to stabilise hashboard temperatures.

Confidence: high

Antminer T19 S19

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes T19 Hydro, T19 Pro Hyd
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; T19 Hydro coolant ~45–55°C → hot water.

Notes: Value tier of the S19 platform; a factory T19 Hydro exists alongside the air model.

Confidence: high

Antminer S19 S19

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S19 Hydro
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; S19 Hydro coolant ~45–55°C → hot water/radiant.

Notes: Base S19 (BM1398). A factory S19 Hydro shipped for rack-dense deployments.

Confidence: high

Antminer S19 Pro / S19 Pro+ S19

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S19 Pro Hyd (177 TH/s), S19 Pro+ Hyd (191–198 TH/s)
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; hydro loop ~45–55°C → hot water/radiant.

Notes: The Pro and Pro+ both ship factory hydro variants at higher hashrate than the air units.

Confidence: high

Antminer S19j Pro / S19k Pro S19

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variant
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat.

Notes: No factory liquid variant for the j Pro / k Pro. Within the S19 line the factory hydro flagships are the S19 Pro Hyd and S19 XP Hyd.

Confidence: high

Antminer S19 XP / S19 XP+ S19

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S19 XP Hyd (257 TH/s), S19 XP+ Hyd (279–293 TH/s), S19e XP Hydro (251 TH/s)
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; hydro loop ~45–55°C → hot water/radiant.

Notes: The 5nm XP (BM1366) tops the S19 line; its factory hydro variants push well past the air hashrate.

Confidence: high

Antminer S21 S21

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S21 Hyd (335 TH/s)
Factory immersion variantYes S21 Immersion (227 / 301 TH/s)
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; hydro/immersion capture a larger share for hot water or radiant loops.

Notes: First S21-generation model with all three factory form factors in the catalog: air, hydro, and a factory Immersion SKU.

Confidence: high

Antminer S21 Pro S21

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variant
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat.

Notes: The S21 Pro (BM1370) ships as an air unit; within the S21 series the factory liquid units are the S21 Hyd/Immersion, S21+ Hyd, S21e Hyd and S21 XP Hyd/Immersion rather than a dedicated "Pro Hyd".

Confidence: medium

Antminer S21+ / S21e S21

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S21+ Hyd (358 TH/s), S21e Hyd (288–332 TH/s), S21e XP Hyd (3U)
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; hydro loop ~45–55°C → hot water/radiant.

Notes: The + and e sub-lines ship factory hydro units, several in a rack-dense 3U form factor.

Confidence: high

Antminer S21 XP S21

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S21 XP Hyd, S21 XP+ Hyd (500 TH/s)
Factory immersion variantYes S21 XP Immersion
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; hydro/immersion capture a larger share for hot water or radiant loops.

Notes: Top of the S21 line; factory air, hydro (incl. a 500 TH/s XP+ Hyd) and a factory Immersion SKU all exist.

Confidence: high

Antminer S23 S23

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variantYes S23 Hyd, S23 Hyd (3U)
Factory immersion variantYes S23 Immersion (368 / 442 TH/s)
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; hydro/immersion capture a larger share for hot water or radiant loops.

Notes: Next-generation flagship; ships in air, hydro (incl. 3U) and a factory Immersion SKU.

Confidence: high

Whatsminer M30S / M30S+ / M30S++ M30

ManufacturerMicroBT
Stock coolingForced air (2 fans)
Factory hydro variantYes M30S++ (Hydro)
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; the M30S++ Hydro loop feeds a hot-water/radiant loop.

Notes: MicroBT ships a factory M30S++ Hydro. (MicroBT also offers hydro/immersion variants in its later M5x/M6x lines; the M30S++ Hydro is the one currently profiled in the D-Central catalog.)

Confidence: high

Whatsminer M50 / M60 series M50/M60

ManufacturerMicroBT
Stock coolingForced air (2 fans)
Factory hydro variantYes M53 / M53S / M53S+ (M50-gen hydro), M63 / M63S / M63S+ (M60-gen hydro)
Factory immersion variantYes M56 / M56S / M56S+ (M50-gen immersion), M66 / M66S (M60-gen immersion)
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat; the M5x/M6x hydro loops feed a hot-water/radiant loop.

Notes: MicroBT encodes cooling in the model number's middle digit: M50/M60 are air, M53/M63 are hydro (water), and M56/M66 are immersion — so each generation ships all three form factors, and all are profiled in the D-Central catalog.

Confidence: high

Antminer L7 / L9 (Scrypt) L (Scrypt)

ManufacturerBitmain
Stock coolingForced air (4 fans)
Factory hydro variant
Factory immersion variant
Aftermarket immersionConvertible — remove fans and submerge the whole unit in dielectric fluid (single- or two-phase). Aftermarket conversion voids the manufacturer warranty and needs a sealed tank + fluid + external heat exchanger.
Heat-reuse fitAir exhaust ~55–70°C → space heat.

Notes: Litecoin/Dogecoin Scrypt miners. The air L7/L9 have no factory liquid variant; the separate, newer L11 line adds a Scrypt hydro tier (the L11 Hyd 2U).

Confidence: high

Factory hydro/immersion cells name a variant only where that exact SKU exists in the live D-Central miner database; cooling-method characteristics are grounded in the D-Central Mining Bible and mirror the cooling-methods comparison. Aftermarket immersion or hydro conversion of an air unit voids the manufacturer warranty — confirm terms with the manufacturer before purchase or conversion. Free CSV/JSON under CC BY 4.0.