Bitmain Antminer S19 Hydro multi-bin reference ASIC miner reference image
OEM support reference Bitmain SHA-256 PRO Hydro

Bitmain Antminer S19 Hydro multi-bin reference

Official Antminer S19 Hydro 208-A reference covering 132-158 TH/s, 4,554-5,451 W and exact three-phase and thermal boundaries.

Hashrate 132-158 TH/s
Power 4,554-5,451 W
Efficiency

Quick answer

The Bitmain Antminer S19 Hydro multi-bin reference is a Bitcoin miner rated about 132-158 TH/s at roughly 4,554 W (about 34.5 J/TH).

Full Specifications

Full technical specifications for this miner.
Model Bitmain Antminer S19 Hydro multi-bin reference
Model Number Antminer S19 Hydro 208-A
Manufacturer Bitmain
Algorithm SHA-256
Hashrate 132-158 TH/s
Power Consumption 4,554-5,451 W
Cooling Hydro
Voltage Range 342-418 V AC three-phase; 47-63 Hz
Operating Temperature 0 C to 40 C ambient
Dimensions 197 x 208.6 x 412 mm including PSU
Weight 15.8 kg net including PSU
Interface RJ45 Ethernet 10/100M
Status OEM support reference

Official hydro multi-bin reference: Bitmain documents the Antminer S19 Hydro as model 208-A in five nominal bins: 132, 138.5, 145, 151.3, and 158 TH/s. This is a liquid-cooled, three-phase machine; its facility requirements cannot be taken from an air-cooled S19.

Nominal bin Rated wall power Rated efficiency
132 TH/s 4,554 W 34.5 J/TH
138.5 TH/s 4,778 W 34.5 J/TH
145 TH/s 5,003 W 34.5 J/TH
151.3 TH/s 5,227 W 34.5 J/TH
158 TH/s 5,451 W 34.5 J/TH

Bitmain applies ±3% to hashrate and ±5% to wall power and efficiency. The published performance basis is Tj 65°C. These bins are not a continuous tuning range.

Electrical and liquid-loop gate

The official input is 342–418 V AC three-phase, 47–63 Hz, with 10 A per wire. The manufacturer lists 20–40°C inlet water, but the cited specification does not establish a flow rate, pressure limit, connector, or fluid chemistry. Do not import those values from another hydro model.

  • Verify the complete 208-A nameplate and exact bin before facility design.
  • Use qualified three-phase distribution, grounding, protection, isolation, leak detection, pumping, filtration, monitoring, and heat rejection.
  • Never energize a hydro miner dry or with an unvalidated loop.

Physical and environmental reference

The server including PSU is 197 × 208.6 × 412 mm and 15.8 kg net. Packaged dimensions are 570 × 316 × 430 mm and gross weight is 17.7 kg. The official range is 0–40°C ambient, −20–70°C storage, 10–90% non-condensing relative humidity, and altitude up to 2,000 m, with temperature derating above 900 m. Network access is RJ45 Ethernet.

Compatibility boundary

S19 Hydro, S19 Pro Hyd., S19 Pro+ Hyd., and S19 XP Hyd. are distinct identities. Do not transfer firmware, recovery media, control boards, PSUs, hashboards, harnesses, coolant specifications, or facility assumptions between them.

Firmware, recovery, and repair

Primary source: Bitmain S19 Hydro specification. Reviewed August 27, 2026.