Skip to content
Bitmain Antminer S19 XP Hyd. k0-10 reference ASIC miner reference image
OEM support reference Bitmain SHA-256 PRO Hydro

Bitmain Antminer S19 XP Hyd. k0-10 reference

Official current Antminer S19 XP Hyd. k0-10 reference: 257 TH/s, 5,346 W and 20.8 J/TH with exact three-phase, coolant and physical requirements.

Hashrate 257 TH/s
Power 5,346 W
Calculated nominal efficiency 20.8016 J/TH

Quick answer

The Bitmain Antminer S19 XP Hyd. k0-10 reference is a Bitcoin miner rated about 257 TH/s at roughly 5,346 W (about 20.8 J/TH).

Full Specifications

Full technical specifications for this miner.
Model Bitmain Antminer S19 XP Hyd. k0-10 reference
Model Number Antminer S19 XP Hyd. k0-10
Manufacturer Bitmain
Algorithm SHA-256
Hashrate 257 TH/s
Power Consumption 5,346 W
Calculated nominal efficiency 20.8016 J/TH
Cooling Hydro
Voltage Range 380-415 V AC three-phase; 50-60 Hz
Operating Temperature 0 C to 40 C ambient
Dimensions 410 x 170 x 209 mm
Weight 12.8 kg net
Interface RJ45 Ethernet 10/100M
Status OEM support reference

Current official hydro reference: Bitmain’s current Antminer S19 XP Hyd. specification identifies version k0-10 at 257 TH/s typical, 5,346 W typical at 35°C inlet water, and 20.8 J/TH. Actual hashrate is ±3%; wall power and efficiency are ±5%.

This reference does not broaden the k0-10 rating into undocumented historic bins. Confirm the full printed model, version, and nameplate values on the unit.

Three-phase electrical requirements

The official input is 380–415 V AC three-phase, 50–60 Hz, with 12 A maximum current. This is not compatible with the 200–240 V assumptions used by air-cooled S19-family equipment. Use qualified distribution, grounding, overcurrent protection, isolation, and installation engineering for the exact nameplate.

Exact liquid-loop requirements

Bitmain specifies 20–40°C coolant inlet temperature, 8–10 L/min flow, no more than 3.5 bar pressure, and an OD10 connector for this k0-10 reference. Never energize the server without validated circulation, heat rejection, leak detection, water quality, and emergency isolation.

The current specification lists antifreeze, pure water, and deionized water with different pH boundaries: 7–9, 6.5–7.5, and 8.5–9.5 respectively. Fluid selection and maintenance must follow the current exact manufacturer document; do not transfer chemistry from another hydro model.

Physical, network, and storage reference

The bare server is 410 × 170 × 209 mm and 12.8 kg net; packaged dimensions are 570 × 316 × 430 mm and gross weight is 14.1 kg. Network access is RJ45 Ethernet 10/100M. The listed storage range is −20–70°C and relative humidity is 10–90% non-condensing.

Exact-name compatibility boundary

S19 XP Hyd., S19 XP+ Hyd., S19e XP Hyd., and air-cooled S19 XP are separate names. Matching hashrate alone does not establish the PSU, control board, hashboard, firmware, recovery image, connector, coolant procedure, or facility requirements.

Firmware, recovery, and repair

Primary sources: Bitmain S19 XP Hyd. specification and official product support hub. Reviewed August 27, 2026.

Primary evidence and scope

Reviewed: 2026-08-27. Links establish only the fields named by their source scope; current economics, availability, support, and network compatibility are not inferred.