Antminer S17 and T17 owner hub: seven exact OEM references
Owner-first S17/T17 reference hub: identify the complete printed model name, suffix, factory lane, installed PSU, control board, and firmware before selecting specifications, parts, recovery media, or repair procedures.
S17, S17 Pro, S17+, S17e, T17, T17+, and T17e are separate OEM identities. A similar case or hashrate does not make their firmware, controller, hashboard, PSU, or operating limits interchangeable.
Seven canonical S17/T17 references
Antminer S17 Pro50/53/56 TH/s · 1,975–2,212 W · 39.5 J/TH
Antminer S17+67/70/73/76 TH/s · 2,680–3,040 W · 40 J/TH
Antminer S17e56/60/64 TH/s · 2,520–2,880 W · 45 J/TH
Antminer T1740 TH/s · 2,200 W · 55 J/TH
Antminer T17+52/55/58/61/64 TH/s · 2,600–3,200 W · 50 J/TH
Antminer T17e50/53 TH/s · 2,750/2,915 W · 55 J/TH
Fast model-resolution table
| Printed model | OEM normal lanes | Boards / chips | Net weight |
|---|---|---|---|
| S17 | 50, 53 TH/s | 3 / 144 | 9.5 kg |
| S17 Pro | 50, 53, 56 TH/s | 3 / 144 | 9.5 kg |
| S17+ | 67, 70, 73, 76 TH/s | 3 / 195 | 9.8 kg |
| S17e | 56, 60, 64 TH/s | 3 / 405 | 11.3 kg |
| T17 | 40 TH/s | 3 / 90 | 9.73 kg |
| T17+ | 52, 55, 58, 61, 64 TH/s | 3 / 132 | 10.2 kg |
| T17e | 50, 53 TH/s | 3 / 234 | 9.91 kg |
These values identify the OEM model-level reference only. Verify the physical nameplate and installed assemblies before acting on a used or modified machine.
Electrical and environmental boundary
All seven reviewed OEM specifications require 200–240 V AC input. A software power limit or lower hashrate target does not create 120 V compatibility. Follow the installed PSU nameplate, connector ratings, overcurrent protection requirements, and applicable electrical code.
The profiles preserve each model’s exact temperature and humidity limits. Published noise is 82 dBA across this family; these are not living-space appliances without engineered acoustic, ventilation, and electrical infrastructure.
Firmware and control-board gate
A family name or hashrate cannot select firmware or recovery media. Used machines may contain replacement controllers, hashboards, PSUs, or mixed revisions.
- Identify the installed control board and collect the current version.
- Match the complete printed model, suffix, board, and exact manufacturer package scope.
- Preserve configuration and logs before any write operation.
- For no boot, missing boards, zero ASIC, thermal faults, instability, package mismatch, interrupted writing, or uncertain identity, request Antminer diagnosis.
Canonical and evidence policy
Individual factory bins formerly published as separate profiles now resolve to their correct multi-bin OEM reference. This hub lists only the seven identities supported by exact manufacturer specification records. D-Central custom builds remain separate from this OEM directory and require their own build evidence.
Reference profiles are historical support records, not live inventory promises. Product availability and transaction terms belong on separate commerce pages.
Primary specification set
- Official S17 specification
- Official S17 Pro specification
- Official S17+ specification
- Official S17e specification
- Official T17 specification
- Official T17+ specification
- Official T17e specification
Reviewed August 27, 2026.
Related products, repair, and setup paths
- how D-Central diagnoses ASIC repairs
- ASIC troubleshooting library
- ASIC manuals and repair guides
- replacement hashboards
- ASIC control boards
- ASIC power supplies
- S19 family replacement hashboard
- C52 replacement control board
- APW12 S19 power supply
- compare specs in the ASIC miner database
- compare ASIC miner specs
- ASIC miner database
- ASIC repair services
- Antminer S19 specs and profitability
- buy a tested Antminer S19
- Antminer S19 maintenance guide
- Antminer S19 repair service
- Antminer S21 specs
- Bitmain Antminer S21
- Antminer S21 maintenance guide
- BM1370BC S21 Pro chip
- Antminer S9 specs
- Bitmain Antminer S9
- Antminer S9 maintenance guide
- S9 hashboard repair parts bundle
Last reviewed August 27, 2026.